Multiple parameters and target optimization of splitter blades for axial spiral blade blood pump using computational fluid mechanics, neural networks, and particle image velocimetry experiment
Open Access
- 1 July 2021
- journal article
- research article
- Published by SAGE Publications in Science Progress
- Vol. 104 (3)
Abstract
The blood pump is an implantable device with strict performance requirements. Any effective structural improvement will help to improve the treatment of patients. However, the research of blood pump structure improvement is a complex optimization problem with multiple parameters and objectives. This study takes the splitter blade as the object of structural improvement. Computational fluid mechanics and neural networks are combined in research and optimization. And hydraulic experiments and micro particle image velocimetry technology were used. In the optimization study, the number of blades, axial length and circumferential offset are optimization parameters, and hydraulic performance and hemolytic prediction index are optimization targets. The study analyzes the influence of each parameter on performance and completes the optimization of the parameters. In the results, the optimal parameters of number of blades, axial length ratio, and circumferential offset are 2.6° and 0.41°, respectively. Under optimized parameters, hydraulic performance can be significantly improved. And the results of hemolysis prediction and micro particle image velocimetry experiments reflect that there is no increase in the risk of hemolytic damage. The results of this study provide a method and ideas for improving the structure of the axial spiral blade blood pump. The established optimization method can be effectively applied to the design and research of axial spiral blade blood pumps with complex, high precision, and multiple parameters and targets.Keywords
This publication has 20 references indexed in Scilit:
- Multivariate Assessment of the Effect of Pump Design and Pump Gap Design Parameters on Blood TraumaArtificial Organs, 2015
- Investigation of the Characteristics of HeartWare HVAD and Thoratec HeartMate II Under Steady and Pulsatile Flow ConditionsArtificial Organs, 2015
- Multi-objective optimization of a low specific speed centrifugal pump using an evolutionary algorithmEngineering Optimization, 2015
- Multilaboratory Study of Flow-Induced Hemolysis Using the FDA Benchmark Nozzle ModelArtificial Organs, 2014
- Unsteady internal flow conditions of mini-centrifugal pump with splitter bladesJournal of Thermal Science, 2013
- Validation of an Axial Flow Blood Pump: Computational Fluid Dynamics Results Using Particle Image VelocimetryArtificial Organs, 2011
- Computational Characterization of Flow and Hemolytic Performance of the UltraMag Blood Pump for Circulatory SupportArtificial Organs, 2010
- Effects of splitter blades on the law of inner flow within centrifugal pump impellerChinese Journal of Mechanical Engineering, 2007
- Three‐Dimensional Numerical Prediction of Stress Loading of Blood Particles in a Centrifugal PumpArtificial Organs, 1995
- Model for a General Mechanical Blood Damage PredictionArtificial Organs, 1995