Readmissions after continuous flow left ventricular assist devices implantation are common. We compared the frequency and etiology of readmissions between two continuous flow left ventricular assist devices 6 months after implant. We retrospectively assessed readmissions in 81 patients who received a bridge to transplant HeartMate-II (HM-II) n = 35, 43% or HeartWare (HW) n = 46, 57%, from 2009 to 2014. Readmissions were divided into cardiac, infection, gastrointestinal bleeding, stroke, pump thrombosis, and miscellaneous profiles. Age, gender, creatinine, INTERMACS profiles were comparable between groups (p > 0.05). Sixty-one patients accounted for 141 readmissions. At 6 months, the overall readmission rate was higher among HM-II versus HW recipients (2.3 ± 1.7 vs. 1.4 ± 1.3; p = 0.024). Multiple readmissions (≥2) occurred more frequently in HM-II recipients (HM-II 23, 66% vs. HW 20, 44%; p = 0.047) which accounted for 87% of overall readmission frequency. Cardiac profile was the most common reason for readmission (HM-II = 15, HW = 17; p = 0.95). Readmission for arrhythmia (HM-II = 10, HW = 3; p = 0.021) and overall infection rate (0.49 ± 0.70 vs. 0.17 ± 0.68; p = 0.001) were more common among HM-II recipients; however, other readmission profiles were comparable between devices (p > 0.05). Readmission frequency, multiple readmissions, and clinical profile characteristics were different between HM-II and HW recipients.Keywords
This publication has 33 references indexed in Scilit:
- The Global Health and Economic Burden of Hospitalizations for Heart FailureJACC, 2014
- Use of Left Ventricular Assist Device (HeartMate II): A Singapore ExperienceArtificial Organs, 2014
- Ambient hemolysis and activation of coagulation is different between HeartMate II and HeartWare left ventricular assist devicesThe Journal of Heart and Lung Transplantation, 2014
- Pump Flow Estimation From Pressure Head and Power Uptake for the HeartAssist5, HeartMate II, and HeartWare VADsASAIO Journal, 2013
- Readmissions After Ventricular Assist Device: Etiologies, Patterns, and Days Out of HospitalThe Annals of Thoracic Surgery, 2013
- Fifth INTERMACS annual report: Risk factor analysis from more than 6,000 mechanical circulatory support patientsThe Journal of Heart and Lung Transplantation, 2013
- The 2013 International Society for Heart and Lung Transplantation Guidelines for mechanical circulatory support: Executive summaryThe Journal of Heart and Lung Transplantation, 2013
- Rehospitalization for Heart FailureJACC, 2013
- Readmissions After Implantation of Axial Flow Left Ventricular Assist DeviceJACC, 2013
- Recent National Trends in Readmission Rates After Heart Failure HospitalizationCirculation: Heart Failure, 2010