We succeeded in using 40 nm FRET (fluorescence resonance energy transfer) microspheres conjugated to antibodies as the fluorescent reporters to perform the multiplexing suspension array measurements on two simulants of biological threats, ricin (A chain) and a crude spore preparation of Bacillus globigii (Bg). The microspheres were impregnated with two types of fluorophores in equal number (∼140 fluorophores in total per microsphere) and displayed bright PE-like fluorescence via a fluorescence resonance energy transfer mechanism. Activated microspheres (aldehyde groups) were directly coupled to antibodies and used to form sandwich-type immunoassays in a suspension array. For the crude preparations of Bg, the assay sensitivity using antibody-conjugated microspheres is an order of magnitude higher than that using the conventional fluorescent reporter, R-phycoerythrin (PE). Using the microspheres, Bg at the concentration of 5 ng/mL can be easily detected. For ricin, the assay sensitivity was similar to that obtained using PE as the reporter, but washing the reaction mixtures resulted in the fluorescence signals that were 2−3 times higher compared to those using PE. Ricin at a concentration of 1 ng/mL can be readily identified. Importantly, the two simulants do not interfere with each other in the multiplexing experiments. The 40 nm FRET microspheres are a new sensitive alternative as fluorescent reporters for detection in suspension arrays.Keywords
This publication has 9 references indexed in Scilit:
- Clonal T-cell Populations and Increased Risk for Cytotoxic T-cell Lymphomas in B-CLL PatientsAmerican Journal of Surgical Pathology, 2004
- Multiplexed SNP genotyping using the QbeadTM system: a quantum dot-encoded microsphere-based assayNucleic Acids Research, 2003
- Comparison of a Multiplex Flow Cytometric Assay with Enzyme-Linked Immunosorbent Assay for Quantitation of Antibodies to Tetanus, Diphtheria, and Haemophilus influenzae Type bClinical and Vaccine Immunology, 2002
- Rapid and sensitive detection of biological warfare agents using time-resolved fluorescence assaysJournal of Immunological Methods, 2002
- Quantitating fluorescence intensity from fluorophore: The definition of MESF assignmentJournal of Research of the National Institute of Standards and Technology, 2002
- Spectral Properties of Single BODIPY Dyes in Polystyrene Microspheres and in SolutionsJournal of Fluorescence, 2001
- A Novel and Robust Homogeneous Fluorescence-Based Assay Using Nanoparticles for Pharmaceutical Screening and DiagnosticsSLAS Discovery, 2000
- Efficient excitation energy transfer among multiple dyes in polystyrene microspheresJournal of Luminescence, 1998
- Green- and red-fluorescent nanospheres for the detection of cell surface receptors by flow cytometryJournal of Immunological Methods, 1998