Validation of the leukocyte labeling procedure with a new kit for the preparation of technetium-99m exametazime injection
Authors:
- Marta Gallego PeinadoMPMarta Gallego Peinado
- Jose Sanchez CatalicioJCJose Sanchez Catalicio
- Florentina Perez AngelFAFlorentina Perez Angel
- Jose Contreras GutiérrezJGJose Contreras Gutiérrez
- 1 April 2016
- journal article
- research article
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 37 (4) , 432-434
Abstract
The labeling of leukocytes with technetium-99m (Tc)-HMPAO is a frequent procedure in our laboratory, which was first validated before initiation of clinical studies with the commercial kit of Tc-D,L-hexamethylpropylene amine oxime (Tc-D,L-HMPAO), available from 1988. Recently, a new kit of exametazime has been introduced, with a similar composition and clinical indications, but with some technical improvements. Validation of the labeling procedure with this new kit is proposed, including a comparison between both commercial kits. Requirements for validation were achieved successfully and a comparative study showed no statistically significant differences; nevertheless, labeling of leukocytes may be expected routinely with the new kit on account of its longer shelf-life and lower cost.Keywords
This publication has 6 references indexed in Scilit:
- Influence of radiolytic‐produced hydrogen peroxide on the stability of commercial kit 99mtechnetium‐exametazime preparationJournal of Labelled Compounds and Radiopharmaceuticals, 2013
- A large retrospective single-centre study to define the best image acquisition protocols and interpretation criteria for white blood cell scintigraphy with 99mTc-HMPAO-labelled leucocytes in musculoskeletal infectionsEuropean Journal of Nuclear Medicine and Molecular Imaging, 2013
- Guidelines for the labelling of leucocytes with 99mTc-HMPAOEuropean Journal of Nuclear Medicine and Molecular Imaging, 2010
- 18F-FDG labelling of human leukocytesNuclear Medicine Communications, 2000
- Radiochemical purity of 99mTc-HM-PAO: Critical parameters during kit preparationNuclear Medicine and Biology, 1995
- CLINICAL EXPERIENCE WITH 99mTc-HEXAMETHYLPROPYLENE-AMINEOXIME FOR LABELLING LEUCOCYTES AND IMAGING INFLAMMATIONThe Lancet, 1986