Downstream Control of Multireach Canal Systems
Authors:
- 1 March 1995
- journal article
- research article
- Published by American Society of Civil Engineers (ASCE) in Journal of Irrigation and Drainage Engineering
- Vol. 121 (2) , 179-190
Abstract
A downstream control algorithm was developed for the control of multireach canal systems. The objective of the control is to maintain a target water level at the downstream end of each pool by adjusting the control gate at the upstream end of the pool. If the measured water level differs from its target value, the gate is adjusted, aiming to eliminate the deviation as soon as possible. The method is based on an explicit solution procedure of the St. Venant equations. Adjustments of each control gate are calculated according to water levels and flow rates at the information nodes downstream of the gate and the water level immediately upstream of it. Unless the pool is extremely long, an effective control can be obtained with only two information nodes in each pool (at the most upstream and downstream ends of the pool). If flow rates at information nodes are estimated using the slope stage method, four water levels are measured in each pool.Keywords
This publication has 7 references indexed in Scilit:
- Downstream Control Algorithm for Irrigation CanalsJournal of Irrigation and Drainage Engineering, 1994
- Control Method for On‐Demand Operation of Open‐Channel FlowJournal of Irrigation and Drainage Engineering, 1993
- Design of Control Algorithm for Operation of Irrigation CanalsJournal of Irrigation and Drainage Engineering, 1992
- Centralized Scheduling Logic for Canal OperationJournal of Irrigation and Drainage Engineering, 1991
- Control of Irrigation Canal NetworksJournal of Irrigation and Drainage Engineering, 1989
- Automatic Control of Canal Flow Using Linear Quadratic Regulator TheoryJournal of Hydraulic Engineering, 1988
- Computer Control for Irrigation‐canal SystemJournal of Irrigation and Drainage Engineering, 1983