Proposed three ratios technique for the interpretation of mineral oil transformers based dissolved gas analysis
Authors:
Open Access
- 10 April 2018
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 12 (11) , 2650-2661
Abstract
Dissolved gas analysis (DGA) of oil is one of the major diagnostic tools that are used to detect the incipient faults of oil‐immersed transformers through the correlation between the dissolved gases content in transformer oil and a particular malfunction. There are several techniques of DGA to interpret the incipient transformer faults such as Doernenburg ratio, Rogers's ratio, IEC ratio and Duval triangle techniques. This study presents a new proposed technique for transformer fault diagnosis using a new three gas ratios concentration of DGA to overcome the conflict that takes place in the traditional interpretation techniques. The accuracy of the proposed diagnosis technique is verified using practical DGA data obtained from 688 samples that have been collected from different transformers of different rating and different lifespan reported by Egyptian Electricity Holding Company, IEC TC10 and related databases surveyed from actual incident cases. The comparison with traditional DGA techniques showed that the proposed DGA ratio technique has good diagnosis accuracy. It is found that the suggested three ratios technique method has 99.86% accuracy as compared with 85.67% for Duval, 75.08% for Doernenburg, 47.34% for IEC and 39% for Rogers when testing 688 cases.Keywords
This publication has 22 references indexed in Scilit:
- Thermodynamic Estimation of Transformer Fault SeverityIEEE Transactions on Power Delivery, 2015
- Application of artificial intelligence in diagnosis of power transformer incipient faults2013
- A new approach to identify power transformer criticality and asset management decision based on dissolved gas-in-oil analysisIEEE Transactions on Dielectrics and Electrical Insulation, 2012
- The duval triangle for load tap changers, non-mineral oils and low temperature faults in transformersIEEE Electrical Insulation Magazine, 2008
- Improving the reliability of transformer gas-in-oil diagnosisIEEE Electrical Insulation Magazine, 2005
- A new data mining approach to dissolved gas analysis of oil-insulated power apparatusIEEE Transactions on Power Delivery, 2003
- Interpretation of gas-in-oil analysis using new IEC publication 60599 and IEC TC 10 databasesIEEE Electrical Insulation Magazine, 2001
- A novel fuzzy logic approach to transformer fault diagnosisIEEE Transactions on Dielectrics and Electrical Insulation, 2000
- Mineral insulating oil in transformersIEEE Electrical Insulation Magazine, 1998
- IEEE and IEC Codes to Interpret Incipient Faults in Transformers, Using Gas in Oil AnalysisIEEE Transactions on Electrical Insulation, 1978