Surface plasmon resonance aided electrochemical immunosensor for CK-MB determination in undiluted serum samples
Authors:
- 8 May 2010
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 397 (5) , 1873-1881
Abstract
This article presents a simple chronoamperometric immunosensor for the quantitative assessment of creatine kinase MB (CK-MB) in 50 µL undiluted serum samples. The immunosensor consists of gold working and counter electrodes patterned onto a glass chip by thin-film photolithography and an external Ag|AgCl reference electrode. The detection limit (DL) of the chronoamperometric method is 13 ng mL−1 (DL = 2×RMSD/S, where RMSD is the residual mean standard deviation of the measured points around a calibration curve with a slope of S). In spiked serum samples, the response was linear up to 300 ng mL−1 of CK-MB. A surface plasmon resonance (SPR) system with simultaneous electrochemical detection (EC-SPR) aided the development of the sandwich immunoassay. Real-time monitoring of the SPR signal was used to optimize the capture antibody immobilization, CK-MB and detection antibody binding, as well as to minimize the nonspecific adsorption of serum proteins to the sensor surface. The detection antibody has been labeled with alkaline phosphatase (ALP) enzyme for sensitive electrochemical detection. ALP catalyzes the hydrolysis of ascorbic acid phosphate and generates ascorbic acid, which is measured chronoamperometrically. The electrochemical immunoassay for CK-MB was less sensitive to nonspecific adsorption related interferences, had a better detection limit, and required a lower volume of sample than the SPR method. SPR (A) and electrochemical (B) cells for CK-MB measurement in serum. (C) counter electrode, (R) reference electrode, (W) working electrode, (r) reference chamber, and (s) signal chamberKeywords
This publication has 40 references indexed in Scilit:
- Microfabricated Amperometric Cells for Multicomponent AnalysisElectroanalysis, 2009
- Protein Quantification in Complex Mixtures by Solid Phase Single-Molecule CountingAnalytical Chemistry, 2009
- A capacitive immunosensor for detection of cholera toxinAnalytica Chimica Acta, 2009
- Novel renewable immunosensors based on temperature-sensitive PNIPAAm bioconjugatesBiosensors and Bioelectronics, 2008
- An in situ electrochemical surface plasmon resonance immunosensor with polypyrrole propylic acid film: Comparison between SPR and electrochemical responses from polymer formation to protein immunosensingBiosensors and Bioelectronics, 2008
- Diagnosis of acute myocardial infarction: CK-MB versus cTn-T in Indian patientsIndian Journal of Clinical Biochemistry, 2008
- An SPR immunosensor for human cardiac troponin T using specific binding avidin to biotin at carboxymethyldextran-modified gold chipClinica Chimica Acta, 2007
- Interfacial pH and surface pKa of a thioctic acid self-assembled monolayerPhysical Chemistry Chemical Physics, 2006
- Myocardial infarction redefined—a consensus document of The Joint European Society of Cardiology/American College of Cardiology committee for the redefinition of myocardial infarctionJACC, 2000
- A disposable amperometric immunosensor for 2,4-dichlorophenoxyacetic acidAnalytica Chimica Acta, 1995