High-intensity focused ultrasound (HIFU) can be applied noninvasively to create focused zones of tissue coagulation on various skin layers. We performed a comparative study of HIFU, evaluating patterns of focused tissue coagulation and ablation upon application thereof. A tissue-mimicking (TM) phantom was prepared with bovine serum albumin and polyacrylamide hydrogel to evaluate the geometric patterns of HIFU-induced thermal injury zones (TIZs) for five different HIFU devices. Additionally, for each device, we investigated histologic patterns of HIFU-induced coagulation and ablation in serial sections of cadaveric skin of the face and neck. All HIFU devices generated remarkable TIZs in the TM phantom, with different geometric values of coagulation for each device. Most of the TIZs seemed to be separated into two or more tiny parts. In cadaveric skin, characteristic patterns of HIFU-induced ablation and coagulation were noted along the mid to lower dermis at the focal penetration depth of 3 mm and along subcutaneous fat to the superficial musculoaponeurotic system or the platysma muscle of the neck at 4.5 mm. Additionally, remarkable pre-focal areas of tissue coagulation were observed in the upper and mid dermis at the focal penetration depth of 3 mm and mid to lower dermis at 4.5 mm. For five HIFU devices, we outlined various patterns of HIFU-induced TIZ formation along pre-focal, focal, and post-focal areas of TM phantom and cadaveric skin of the face and neck.Keywords
This publication has 14 references indexed in Scilit:
- Comparative histometric analysis of the effects of high-intensity focused ultrasound and radiofrequency on skinJournal of Cosmetic and Laser Therapy, 2015
- Thermal ablation of tumours: biological mechanisms and advances in therapyNature Reviews Cancer, 2014
- Histological and Ultrastructural Effects of Ultrasound-induced Cavitation on Human Skin Adipose TissuePlastic and Reconstructive Surgery - Global Open, 2013
- A Tissue Mimicking Polyacrylamide Hydrogel Phantom for Visualizing Thermal Lesions Generated by High Intensity Focused UltrasoundUltrasound in Medicine & Biology, 2013
- Selective transcutaneous delivery of energy to porcine soft tissues using intense ultrasound (IUS)Lasers in Surgery and Medicine, 2008
- High intensity focused ultrasound: Physical principles and devicesInternational Journal of Hyperthermia, 2007
- Basic principles of thermal dosimetry and thermal thresholds for tissue damage from hyperthermiaInternational Journal of Hyperthermia, 2003
- Histopathological changes associated with high intensity focused ultrasound (HIFU) treatment for localised adenocarcinoma of the prostateJournal of Clinical Pathology, 2000
- Thermal dose determination in cancer therapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1984
- TRACKLESS LESIONS IN NERVOUS TISSUES PRODUCED BY HIGH INTENSITY FOCUSED ULTRASOUND (HIGH-FREQUENCY MECHANICAL WAVES)1968