How Many Proximal Screws Are Needed for a Stable Proximal Humerus Fracture Fixation?
Authors:
Open Access
- 1 January 2021
- journal article
- research article
- Published by SAGE Publications in Geriatric Orthopaedic Surgery & Rehabilitation
- Vol. 12
Abstract
Purpose: This biomechanical study investigates the optimal number of proximal screws for stable fixation of a 2-part proximal humerus fracture model with a locking plate. Methods: Twenty-four proximal humerus fracture models were included in the study. An unstable 2-part fracture was created and fixed by a locking plate. Cyclic loading and load-to-failure tests were used for the following 4 groups based on the number of screws used: 4-screw, 6-screw, 7-screw, and 9-screw groups. Interfragmentary gaps were measured following cyclic loading and compared. Consequently, the load to failure, maximum displacement, stiffness, and mode of failure at failure point were compared. Results: The interfragmentary gaps for the 4-screw, 6-screw, 7-screw, and 9-screw groups were significantly reduced by 0.24 ± 0.09 mm, 0.08 ± 0.06 mm, 0.05 ± 0.01 mm, and 0.03 ± 0.01 mm following 1000 cyclic loading, respectively. The loads to failure were significantly different between the groups with the 7-screw group showing the highest load to failure. The stiffness of the 7-screw group was superior compared with the 6-screw, 9-screw, and 4-screw groups. The maximum displacement before failure showed a significant difference between the comparative groups with the 4-screw group having the lowest value. The 7-screw group had the least structural failure rate (33.3%). Conclusion: At least 7 screws would be optimal for proximal fragment fixation of proximal humerus fractures with medial comminution to minimize secondary varus collapse or fixation failure. Level of Evidence: Basic science study.Keywords
This publication has 34 references indexed in Scilit:
- Treatment for displaced proximal humerus fractures: comparison of interlocking plate fixation versus minimal invasive techniquesEuropean Journal of Orthopaedic Surgery & Traumatology, 2013
- Proximal humeral fracture fixation: a biomechanical comparison of two constructsJournal of Shoulder and Elbow Surgery, 2013
- The weight of nations: an estimation of adult human biomassBMC Public Health, 2012
- Fracture fixation with two locking screws versus three non-locking screwsBone & Joint Research, 2012
- Medial support by fibula bone graft in angular stable plate fixation of proximal humeral fractures: an in vitro study with synthetic boneJournal of Shoulder and Elbow Surgery, 2011
- Electrophysiological Assessment of the Deltoid Muscle after Minimally Invasive Treatment of Proximal Humerus Fractures - A Clinical ObservationThe Open Orthopaedics Journal, 2011
- The Biomechanics of Locked Plating for Repairing Proximal Humerus Fractures With or Without Medial Cortical SupportJournal of Trauma: Injury, Infection & Critical Care, 2010
- Locked Plate Fixation of Osteoporotic Humeral Shaft Fractures: Are Two Locking Screws Per Segment Enough?Journal of Orthopaedic Trauma, 2010
- Minimally Invasive Application of the Non-Contact-Bridging (NCB) Plate to the Proximal Humerus: An Anatomical StudyJournal of Orthopaedic Trauma, 2007