Magnetic Resonance Imaging of Cochlear Implant Recipients
Authors:
- 1 July 2016
- journal article
- cochlear implants
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 37 (6) , 665-671
Abstract
Objective: Determine the diagnostic usefulness of postimplantation 1.5 T magnetic resonance imaging (MRI) and review magnet-related MRI complications. Study Design: Retrospective chart review with additional review of MRIs. Setting: Tertiary care children's hospital. Patients: Twelve patients who underwent MRI after receiving a cochlear implant (CI). Intervention: One or more episodes of 1.5 T MRI with CI in place. Main Outcome Measures: Occurrence of magnet-related complications; whether imaging was clinically useful. Results: The 12 patients underwent 23 episodes of MRI, including 13 episodes in 11 patients (18 ears) during which a magnet was present and 17 studies were obtained. Complications related to the magnet occurred during 4 of the 13 imaging episodes (30.8%), all during body or spine studies. Magnet torsion with reversal of polarity occurred in three devices; reduced magnet strength in one; and displacement of the magnet from its housing in one. One patient required surgical magnet replacement, whereas other headpiece retention problems were resolved without surgery. All studies but one brain with bilateral magnets were clinically useful. Conclusions: CI patients who undergo MRI with a magnet in situ may experience complications, especially when imaged below the head. Most complications may be resolved without surgery. Diagnostic usefulness of non-cranial MRI is not likely to be limited by presence of the magnet, while a magnet may prevent clinically useful brain imaging. Obtaining MRI with the magnet in situ avoids the cost and risks associated with multiple surgeries to remove and replace the magnet or the entire implant.Keywords
This publication has 14 references indexed in Scilit:
- Magnetic Resonance Imaging With Cochlear Implant Magnet in PlaceOtology & Neurotology, 2015
- Adverse Events and Discomfort During Magnetic Resonance Imaging in Cochlear Implant RecipientsJAMA Otolaryngology–Head & Neck Surgery, 2015
- Magnet Dislocation: An Increasing and Serious Complication Following MRI in Patients with Cochlear ImplantsRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2014
- MRI Information for Commonly Used Otologic Implants: Review and UpdateOtolaryngology–Head and Neck Surgery, 2014
- Cochlear implants and magnetic resonance scans: A case report and reviewCochlear Implants International, 2013
- Use of Diagnostic Imaging Studies and Associated Radiation Exposure for Patients Enrolled in Large Integrated Health Care Systems, 1996-2010JAMA, 2012
- Magnetic Resonance Imaging at 1.5 T After Cochlear ImplantationOtology & Neurotology, 2010
- Has Pediatric CT at Children's Hospitals Reached Its Peak?American Journal of Roentgenology, 2010
- Cochlear Implant Magnet Displacement During Magnetic Resonance ImagingOtology & Neurotology, 2008
- Safety Study of the Cochlear Nucleus® 24 Device with Internal Magnet in the 1.5 Tesla Magnetic Resonance Imaging ScannerThe Laryngoscope, 2006