Efficacy of the stand‐alone Cox‐Maze IV procedure in patients with longstanding persistent atrial fibrillation
- 10 June 2021
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 32 (10) , 2884-2894
Abstract
Introduction: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia, and results in significant morbidity and mortality. The Cox‐Maze IV procedure (CMP‐IV) has been shown to have excellent efficacy in returning patients to sinus rhythm, but there have been few reports of late follow‐up in sizable cohorts of patients with longstanding persistent AF, the most difficult type of AF to treat.Methods and Results: Between May 2003 and March 2020, 174 consecutive patients underwent a stand‐alone CMP‐IV for longstanding persistent AF. Rhythm outcome was assessed postoperatively for up to 10 years, primarily via prolonged monitoring (Holter monitor, pacemaker interrogation, or implantable loop recorder). Fine‐Gray regression was used to investigate factors associated with atrial tachyarrhythmia (ATA) recurrence, with death as a competing risk. Median duration of preoperative AF was 7.8 years (interquartile range: 4.0–12.0 years), with 71% (124/174) having failed at least one prior catheter‐based ablation. There were no 30‐day mortalities. Freedom from ATAs was 94% (120/128), 83% (53/64), and 88% (35/40) at 1, 5, and 7 years, respectively. On regression analysis, preoperative AF duration and early postoperative ATAs were associated with late ATAs recurrence.Conclusion: Despite the majority of patients having a long‐duration of preoperative AF and having failed at least one catheter‐based ablation, the stand‐alone CMP‐IV had excellent late efficacy in patients with longstanding persistent AF, with low morbidity and no mortality. We recommend consideration of stand‐alone CMP‐IV for patients with longstanding persistent AF who have failed or are poor candidates for catheter ablation.Keywords
All Related Versions
Funding Information
- Foundation for Barnes-Jewish Hospital
This publication has 39 references indexed in Scilit:
- Long-Term Results of a Minimally Invasive Surgical Pulmonary Vein Isolation and Ganglionic Plexi Ablation for Atrial FibrillationPLOS ONE, 2013
- Minimally Invasive Stand-Alone Cox-Maze Procedure for Patients With Nonparoxysmal Atrial FibrillationThe Annals of Thoracic Surgery, 2013
- Long‐term Outcomes of Catheter Ablation of Atrial Fibrillation: A Systematic Review and Meta‐analysisJournal of the American Heart Association, 2013
- The Cox-Maze Procedure for Lone Atrial FibrillationCirculation: Arrhythmia and Electrophysiology, 2012
- Evaluation of risk stratification schemes for ischaemic stroke and bleeding in 182 678 patients with atrial fibrillation: the Swedish Atrial Fibrillation cohort studyEuropean Heart Journal, 2012
- Efficacy and safety of catheter ablation versus antiarrhythmic drugs for atrial fibrillation: a meta-analysis of randomized trialsJournal of Cardiovascular Medicine, 2010
- Animal studies of epicardial atrial ablationHeart Rhythm, 2009
- Trends in catheter ablation for atrial fibrillation in the United StatesJournal of Hospital Medicine, 2009
- The effect of ablation technology on surgical outcomes after the Cox-maze procedure: A propensity analysisThe Journal of Thoracic and Cardiovascular Surgery, 2007
- A prospective, single-center clinical trial of a modified Cox maze procedure with bipolar radiofrequency ablationThe Journal of Thoracic and Cardiovascular Surgery, 2004