Thermally stimulated currents in undoped poly(p-phenylene vinylene) and the effect of stretching

Authors:

Abstract
Thermally stimulated current (TSC) measurements have been performed on undoped stretched poly(p-phenylene vinylene) (PPV). Two TSC peaks P1 and P2 are observed and become smaller as the stretching ratio was gradually increased. The trap depths are evaluated from the initial increasing part of each separated peak by the thermal cleaning method to be about 0.36 eV and 0.55 eV for peaks P1 and P2, respectively, regardless of the stretching ratio. However, the second peak P2 is markedly suppressed on stretching. Peak P1 is interpreted as originating from electron traps formed by impurities such as a bromine (Br2) or sulphur trioxide (SO3) which were not eliminated by heat treatment. In contrast peak P2 was confirmed to be based on defects already existing in the amorphous parts of PPV since the crystallinity in PPV increases and the spin density evaluated by integration of the electron spin resonance spectra in stretched PPV decreases on increasing the stretching ratio.

This publication has 14 references indexed in Scilit: