Evaluation of thoracic pedicle morphometry in a Chinese population using 3D reformatted CT
Authors:
- 30 August 2011
- journal article
- research article
- Published by Wiley in Clinical Anatomy
- Vol. 25 (4) , 461-467
Abstract
The aim of this study was to investigate the detailed three-dimensional morphology of the pedicles from T1 to T12 in 120 Chinese patients using a light-speed Vct CT (General Electric). After reformatting the original images, the following parameters were studied: outer pedicle width (OPW), outer pedicle height (OPH), pedicle chord length (PCL), pedicle cortical thickness (PCT) of the isthmus, and transverse pedicle angle (TPA). The mean outer pedicle width, outer pedicle height, and pedicle chord length were significantly smaller in females than in males at all levels (P < 0.01). The percentage of outer pedicle width ≤5.0 mm and ≤4.5 mm was high at mid-thoracic pedicles. No significant differences were found in transverse pedicle angle and pedicle cortical thickness in males and females. Pedicle cortical thickness was significantly thinner in patients over 50 years old compared with patients below 50 years old at most levels. The results showed that a screw of larger than 4.5 mm would be too large for mid-thoracic segments in Chinese population, especially for female patients. Considering the amount of variation between individuals and the complicated structure of the thoracic pedicles, the use of the transpedicular screw fixation must be individualized for each patient and based on detailed preoperative assessment. Reformatted CT assessment is essential before this procedure is performed. Clin. Anat. 25:461–467, 2012.Keywords
This publication has 37 references indexed in Scilit:
- Reformatted computed tomographic evaluation of the thoracic pedicle in a Chinese population for the surgical application of transpedicular screw placementSurgical and Radiologic Anatomy, 2009
- Accuracy and safety of pedicle screw fixation in thoracic spine traumaJournal of Neurosurgery: Spine, 2006
- Pedicle and Transverse Process Screws of the Upper Thoracic SpineSpine, 1999
- Projection of the Thoracic Pedicle and Its Morphometric AnalysisSpine, 1997
- Outcome after limited posterior surgery for thoracic and lumbar spine metastasesEuropean Spine Journal, 1996
- Internal Architecture of the Thoracic PedicleSpine, 1996
- Clinical importance of the minimal cancellous diameter of lower thoracic and lumbar vertebral pediclesClinical Anatomy, 1996
- Real minimal diameter of the lower thoracic and lumbar vertebral pediclesClinical Anatomy, 1994
- Influence of Bone Mineral Density on the Fixation of Thoracolumbar Implants A Comparative Study of Transpedicular Screws, Laminar Hooks, and Spinous Process WiresSpine, 1990
- Morphometry of the Thoracic and Lumbar Spine Related to Transpedicular Screw Placement for Surgical Spinal FixationSpine, 1988