On-Chip Transportation and Measurement of Mechanical Characteristics of Oocytes in an Open Environment
Open Access
- 22 May 2015
- journal article
- research article
- Published by MDPI AG in Micromachines
- Vol. 6 (5) , 648-659
Abstract
We propose a system that transports oocytes and measures their mechanical characteristics in an open environment using a robot integrated microfluidic chip (chip). The cells are transported through a micropillar array in the chip, and their characteristics are measured by a mechanical probe and a force sensor. Because the chip has an open microchannel, important cells such as oocytes are easily introduced and collected without the risk for losing them. In addition, any bubbles trapped in the chip, which degrade the measurement precision, are easily removed. To transport the oocytes through the open microchannel, we adopt a transportation technique based on a vibration-induced flow. Under this flow, oocytes arrive at the measurement point, where their mechanical characteristics are determined. We demonstrate the introduction, transportation, measurement of mechanical characteristics, and collection of oocytes using this system.Keywords
Funding Information
- SPS Grant-in-Aid for Challenging Exploratory Research (15K13909)
This publication has 27 references indexed in Scilit:
- In situ mechanical characterization of mouse oocytes using a cell holding deviceLab on a Chip, 2010
- Estimating Young's modulus of zona pellucida by micropipette aspiration in combination with theoretical models of ovumJournal of The Royal Society Interface, 2009
- Measuring the mechanical behaviour of human oocytes with a very simple SU-8 micro-toolBiomedical Microdevices, 2007
- Association between human oocyte developmental competence and expression levels of some cumulus genesReproduction, 2007
- Mouse zona pellucida dynamically changes its elasticity during oocyte maturation, fertilization and early embryo developmentHuman Cell, 2006
- Measurement and Characterization of Whole-Cell Mechanical BehaviorAnnals of Biomedical Engineering, 2006
- Investigating Protein Structure Change in the Zona Pellucida with a Microrobotic SystemThe International Journal of Robotics Research, 2005
- Mechanical property characterization of mouse zona pellucidaIEEE Transactions on Nanobioscience, 2003
- Measurement of cell density and necrotic fraction in human melanoma xenografts by diffusion weighted magnetic resonance imagingMagnetic Resonance in Medicine, 2000
- Measurement of local diffusion coefficients in biofilms by microinjection and confocal microscopyBiotechnology and Bioengineering, 1997