Small Animal Absorbed Radiation Dose from Serial Micro-Computed Tomography Imaging
- 7 February 2007
- journal article
- research article
- Published by Springer Nature in Molecular Imaging and Biology
- Vol. 9 (2) , 78-82
Abstract
To determine the radiation dose to mouse cancer xenografts from serial micro-computed tomography (CT) examinations. A nude mouse with a 15-mm subcutaneous pancreatic cancer xenograft in the rightflank was used. Radiation exposure to the subcutaneous tumor and the mouse pancreas (to simulate an orthotopic pancreatic tumor model) was measured using lithium fluoride thermoluminescent dosimeters. Ultrafast micro-CT was performed using 80 kVp, 0.26 mA, 0.156 mm slice thickness, 256 slices, 0.7 mm Al filtration, and 60-second image acquisition time (15 mA second). Micro-CT imaging acquisitions were repeated four times. We measured consistently low tumor doses (0.014 to 0.02 Gy; average = 0.017 Gy) per scan. Orthotopic doses in the region of the pancreas were also consistently low (0.014 to 0.018 Gy; average = 0.016 Gy) per scan. Radiation doses delivered during ultrafast micro-CT serial imaging in the mouse are low and are likely below the threshold to affect tumor growth.Keywords
This publication has 15 references indexed in Scilit:
- In Vivo Quantitation of Intratumoral Radioisotope Uptake Using Micro-Single Photon Emission Computed Tomography/Computed TomographyMolecular Imaging and Biology, 2006
- Radiation therapy and combined modality treatment of gastrointestinal carcinomasCancer Treatment Reviews, 2006
- Monte Carlo simulations of dose from microCT imaging procedures in a realistic mouse phantomMedical Physics, 2005
- Phase I and pharmacokinetic study of the novel redox-active agent, motexafin gadolinium, with concurrent radiation therapy in patients with locally advanced pancreatic or biliary cancersCancer Chemotherapy and Pharmacology, 2005
- Tumor Response Assessment Is More Robust With Sequential CT Scanning Than External Caliper Measurements1Academic Radiology, 2005
- Micro-Computed Tomography—Current Status and DevelopmentsAnnual Review of Biomedical Engineering, 2004
- Small-Animal X-ray Dose from Micro-CTMolecular Imaging, 2004
- In Vivo Respiratory-Gated Micro-CT Imaging in Small-Animal Oncology ModelsMolecular Imaging, 2004
- Fundamental image quality limits for microcomputed tomography in small animalsMedical Physics, 2003
- Simultaneous molecular and anatomical imaging of the mousein vivoPhysics in Medicine & Biology, 2002