Doppler sonography for the diagnosis of carpal tunnel syndrome: A critical review
Authors:
- 14 July 2014
- journal article
- review article
- Published by Wiley in Muscle & Nerve
- Vol. 50 (2) , 159-163
Abstract
Introduction: Doppler sonography may detect increased intraneural blood flow of the median nerve in carpal tunnel syndrome (CTS). The purpose of this review is to critically evaluate the literature about the diagnostic value of increased intraneural flow detected by sonography in CTS Methods: Systematic review of studies published between 1985 and 2013. Results: The 7 studies we found had considerable differences in study design and had methodological shortcomings. Doppler sonography had a median sensitivity of 72% (range, 41–95%) and a median specificity of 88% (range, 71–100%). Most studies could not compare the diagnostic value of sonography to that of electrophysiological studies, because the latter were often used as a reference test. Conclusions: Increased intraneural flow detected by Doppler sonography may be a promising diagnostic test for CTS, but further studies are needed before it can be implemented in clinical practice. Muscle Nerve 50:159–163, 2014Keywords
This publication has 28 references indexed in Scilit:
- Provocation tests in doppler ultrasonography for carpal tunnel syndromeMuscle & Nerve, 2012
- Increased nerve vascularization detected by color doppler sonography in patients with ulnar neuropathy at the elbow indicates axonal damageMuscle & Nerve, 2012
- Morphologic Characterization of Intraneural Flow Associated With Median Nerve PathologyJournal of Diagnostic Medical Sonography, 2011
- Diagnostic Accuracy of Ultrasonography VS. Electromyography in Carpal Tunnel Syndrome: A Systematic Review of LiteratureUltrasound in Medicine & Biology, 2011
- Combined Doppler and B-mode sonography in carpal tunnel syndromeJournal of the Neurological Sciences, 2011
- Combination of high-resolution and color Doppler ultrasound in diagnosis of carpal tunnel syndromeActa Radiologica, 2011
- Principles of Doppler ultrasound2010
- Value of Power Doppler and Gray-Scale US in the Diagnosis of Carpal Tunnel Syndrome: Contribution of Cross-Sectional Area just before the Tunnel Inlet as Compared with the Cross-Sectional Area at the TunnelKorean Journal of Radiology, 2010
- Schwann cells upregulate vascular endothelial growth factor secondary to chronic nerve compression injuryMuscle & Nerve, 2005
- Sonography in the diagnosis of carpal tunnel syndrome: A critical review of the literatureMuscle & Nerve, 2002