Design and Analysis of a Unique Electrode Configuration Targeting Fringing Field Utilization for Improved Chemicapacitor Sensitivity

Authors:

Abstract
A novel electrode configuration is proposed in this article that targets fringing field utilization as a critical design parameter to enhance sensitivity. In this work, the electrode architecture is the cornerstone in enhancing the chemicapacitor sensitivity as compared to existing literature that often use the sensing material as the primary focus to achieve low-level detection. The proposed electrode configuration consists of multiple dimple-shaped interdigitated electrodes. The results obtained from the finite element analysis conducted in this work reveal that it is possible to increase fringing field utilization by up to 82% by adopting this unique electrode geometry. The proposed design along with the conventional sensor designs are micromachined using PolyMUMPs fabricated electrodes and a PVA polymer sensing material is used to measure the output capacitance as a proof of concept. When exposed to 40-85% humidity in the same controlled environment, the proposed design offers a 76-149 times greater sensitivity compared to the conventional designs. As such, the findings of this research suggest a means to ameliorate chemicapacitor gas sensors for low-level detection, which can be implemented in agricultural greenhouses to monitor the controlled plant growing environment, among many other applications.
Funding Information
  • Ontario Greenhouse Vegetable Growers
  • Natural Science and Engineering Research Council of Canada
  • Canadian Microelectronics Corporation
  • University of Windsor