Abstract
A patient developed an epidural haematoma 6 days after removal of an epidural catheter resulting in paraplegia and death. Insertion and removal of the epidural catheter during anticoagulation with prophylactic unfractionated heparin and subsequent administration of high-dose enoxaparin (Clexane), which commenced 3 days after catheter removal, were implicated.