Time to intubation with McGrath™ videolaryngoscope versus direct laryngoscope in powered air-purifying respirator: a randomised controlled trial
Open Access
- 24 October 2021
- journal article
- research article
- Published by Wolters Kluwer Health in Singapore Medical Journal
- Vol. 65 (1) , 2-8
Abstract
Introduction: During the coronavirus disease 2019 (COVID-19) pandemic, multiple guidelines have recommended videolaryngoscope (VL) for tracheal intubation. However, there is no evidence that VL reduces time to tracheal intubation, and this is important for COVID-19 patients with respiratory failure. Methods: To simulate intubation of COVID-19 patients, we randomly assigned 28 elective surgical patients to be intubated with either McGrath™ MAC VL or direct laryngoscope (DL) by specialist anaesthetists who donned 3M™ Jupiter™ powered air-purifying respirators (PAPR) and N95 masks. The primary outcome was time to intubation. Results: The median time to intubation was 61 s (interquartile range [IQR] 37–63 s) and 41.5 s (IQR 37–56 s) in the VL and DL groups, respectively (P = 0.35). The closest mean distance between the anaesthetist and patient during intubation was 21.6 ± 4.8 cm and 17.6 ± 5.3 cm in the VL and DL groups, respectively (P = 0.045). There were no significant differences in the median intubation difficulty scale scores, proportion of successful intubations at the first laryngoscopic attempt and proportion of intubations requiring adjuncts. All the patients underwent successful intubation with no adverse event. Conclusion: There was no significant difference in the time to intubation of elective surgical patients with either McGrath™ VL or DL by specialist anaesthetists who donned PAPR and N95 masks. The distance between the anaesthetist and patient was significantly greater with VL. When resources are limited or disrupted during a pandemic, DL could be a viable alternative to VL for specialist anaesthetists.Keywords
This publication has 28 references indexed in Scilit:
- Endotracheal intubation with a video-assisted semi-rigid fiberoptic stylet by prehospital providersInternational Journal of Emergency Medicine, 2014
- Utility of the Pentax-AWS in performing tracheal intubation while wearing chemical, biological, radiation and nuclear personal protective equipment: a randomised crossover trial using a manikinEmergency Medicine Journal, 2013
- Expected difficult tracheal intubation: a prospective comparison of direct laryngoscopy and video laryngoscopy in 200 patientsBritish Journal of Anaesthesia, 2009
- Personal protection equipment for biological hazards: Does it affect tracheal intubation performance?Resuscitation, 2007
- The effects of a personal protection system on the performance of a simulated endotracheal intubationCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2006
- Comparison of fibreoptic‐guided orotracheal intubation through classic and single‐use laryngeal mask airways*Anaesthesia, 2005
- SARS among Critical Care Nurses, TorontoEmerging Infectious Diseases, 2004
- Antichemical Protective Gear Prolongs Time to Successful Airway ManagementAnesthesiology, 2004
- Illness in Intensive Care Staff after Brief Exposure to Severe Acute Respiratory SyndromeEmerging Infectious Diseases, 2003
- The Intubation Difficulty Scale (IDS)Anesthesiology, 1997