Intraocular pressure reference intervals in different laboratory animal species
Open Access
- 30 April 2026
- journal article
- Published by Saint-Petersburg State University of Veterinary Medicine in International Journal of Veterinary Medicine
- No. 1,p. 243-253
Abstract
Ophthalmotonometry is a non-invasive method for recording intraocular pressure (IOP) and is widely used in preclinical studies for the early detection of toxic effects and a comprehensive assessment of the pharmacological activity of drugs. This article presents the reference intervals for intraocular pressure in cynomolgus macaques, dwarf pigs, rats, and Pannon and Soviet Chinchilla rabbits. The reference intervals were obtained from healthy cynomolgus macaques (n=50), Wistar rats (n=80), dwarf pigs (n=36), Soviet Chinchilla (n=80), and White Pannon (n=62) rabbits at JSC NPO DOM PHARMATII between May 2024 and July 2025. Measurements were performed in sexually mature and immature males and females (non-pregnant and nulliparous, ignoring the estrous cycle phase). Measurements were performed using a TonoVet veterinary tonometer on male and female laboratory animals of various ages. The smallest variation in individual IOP values was observed in Soviet Chinchilla and White Pannon rabbits, not exceeding 10.5%. The vast majority of studies published in experimental ophthalmology use New Zealand albino rabbits (a New Zealand breed). However, excluding animals with melanin-containing eyes significantly reduces the translational value of the research, as most humans have pigmented eyes. These results can be used in preclinical drug toxicity studies, in assessing the pharmacological activity of antihypertensive drugs in in vivo glaucoma models, and in diagnosing diseases in exotic animals.Keywords
This publication has 20 references indexed in Scilit:
- Investigation into the usefulness of cynomolgus monkeys with spontaneously elevated intraocular pressure as a model for glaucoma treatment researchJournal of Pharmacological Sciences, 2023
- Repeatability, reproducibility, and agreement of three tonometers for measuring intraocular pressure in rabbitsScientific Reports, 2021
- Inducible rodent models of glaucomaProgress in Retinal and Eye Research, 2020
- Glaucoma2018
- Porcine OphthalmologyVeterinary Clinics of North America: Food Animal Practice, 2010
- Aqueous humor formation2009
- Adaptive features of aquatic mammals' eyeThe Anatomical Record, 2007
- The pig eye as a novel model of glaucomaExperimental Eye Research, 2005
- The Induction/Impact Tonometer: a New Instrument to Measure Intraocular Pressure in the RatExperimental Eye Research, 2001
- Binding of Drugs to Eye Melanin Is Not Predictive of Ocular ToxicityRegulatory Toxicology and Pharmacology, 1998