Accurate prediction of transmission through a lensed row-column addressed array
- 1 May 2022
- journal article
- conference paper
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 151 (5) , 3207-3218
Abstract
Using a diverging lens on a row-column array (RCA) can increase the size of its volumetric image and thus significantly improve its clinical value. Here, a ray tracing method is presented to predict the position of the transmitted wave so that it can be used to make beamformed images. The usable transmitted field-of-view (FOV) is evaluated for a lensed 128 + 128 element RCA by comparing the theoretic prediction of the emitted wavefront position with three-dimensional (3D) finite element simulation of the emitted field. The FOV of the array is found to be in the direction orthogonal to the emitting elements and 28.5°–51.2°, depending on depth and element position, for the direction lying along the element. Moreover, the proposed ray tracing method is compared with a simpler thin lens model, and it is shown that the improved accuracy of the proposed method can increase the usable transmitted FOV up to 25.1°.
Keywords
Funding Information
- Højteknologifonden (82-2014-4)
- Innovationsfonden (7050-00004B)
This publication has 13 references indexed in Scilit:
- 3-D imaging using row-column-addressed arrays with integrated apodization - part i: apodization design and line element beamformingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2015
- Top-orthogonal-to-bottom-electrode (TOBE) CMUT arrays for 3-D ultrasound imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2014
- Beamforming of sound from two-dimensional arrays using spatial matched filtersThe Journal of the Acoustical Society of America, 2013
- Real-time volume imaging using a crossed electrode arrayIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2009
- A 256 x 256 2-D array transducer with row-column addressing for 3-D rectilinear imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2009
- In vivo examples of synthetic aperture vector flow imaging2007
- On the focal point of a lens: beyond the paraxial approximationEuropean Journal of Physics, 2006
- The impact of sound speed errors on medical ultrasound imagingThe Journal of the Acoustical Society of America, 2000
- Two-Dimensional Random Arrays for Real Time Volumetric ImagingUltrasonic Imaging, 1994
- Measurement and Specification of Ultrasonic LensesThe Journal of the Acoustical Society of America, 1947