Abstract
Purposes: To quantify the changes in corneal temperature resulting from intensive warm compress (WC) application with minimal pressure and to review the significance of these changes within the context of the peer-reviewed literature. Methods: WC were applied intensively and unilaterally at 45 ± 0.5°C for 30 minutes with the contralateral eye serving as a control. Outer upper eyelid and central corneal surface temperatures were measured using an Infrared pyrometer at baseline. The WC were removed for repeat measurements of the outer upper eyelid surface and central corneal temperatures every 2 minutes and replaced with a new WC heated to 45 ± 0.5°C. Lid and corneal temperatures were monitored for 10 minutes after the final WC application. Results: The mean age of the subjects was 37.1 ± 15.0 years (n = 12). The mean maximum outer upper lid temperature of 42.2 ± 1.3°C was reached after 6 minutes. The mean maximum corneal temperature of 39.4 ± 0.7°C was reached after 8 minutes of heating. The control eye showed no significant change in temperature from baseline throughout the experimental period. Conclusions: These data show that WC use for lid warming, even when only minimal contact pressure is applied, also transfers significant heat to the cornea. Corneal temperatures reach peak temperature after about 8 minutes of WC application. Recent reports discussing the increased potential for transient and long-term corneal molding subsequent to the heat and pressure of WC application are briefly reviewed.Keywords
This publication has 32 references indexed in Scilit:
- The International Workshop on Meibomian Gland Dysfunction: Report of the Subcommittee on Management and Treatment of Meibomian Gland DysfunctionInvestigative Ophthalmology & Visual Science, 2011
- Nonobvious Obstructive Meibomian Gland DysfunctionCornea, 2010
- Inner Eyelid Surface Temperature as a Function of Warm Compress MethodologyOptometry and Vision Science, 2008
- Efficacy of a New Warm Moist Air Device on Tear Functions of Patients With Simple Meibomian Gland DysfunctionCornea, 2006
- Ocular rosacea: an update on pathogenesis and therapyCurrent Opinion in Ophthalmology, 2004
- The treatment of acute dacryocystitis using laser assisted endonasal dacryocystorhinostomyBritish Journal of Ophthalmology, 2004
- Increase in Tear Film Lipid Layer Thickness Following Treatment with Warm Compresses in Patients with Meibomian Gland DysfunctionEye & Contact Lens: Science & Clinical Practice, 2003
- Anterior Ocular Infections: An Overview of Pathophysiology and TreatmentAnnals of Pharmacotherapy, 2000
- Eyelid problemsPostgraduate Medicine, 1986
- Acute Orbital CellulitisArchives of Ophthalmology (1950), 1976