Principles for different modes of multiple‐injection CZE
Authors:
- 28 October 2008
- journal article
- ce and-cec
- Published by Wiley in Electrophoresis
- Vol. 29 (19) , 3952-3958
Abstract
This paper introduces four different modes of multiple‐injection CZE (MICZE). The validity of these MICZE models was evaluated by the experimental data. Prior to the application of MICZE, the electrophoretic conditions are developed in the single‐injection mode by adjusting different experimental parameters such as pH, type and concentration of buffer additives and temperature. Based on the migration time difference (Δtmig) between the analyte and the internal standard or injection marker, one or more MICZE modes can be employed. The injection marker is added to the sample to compensate for injection‐volume fluctuations. The inter‐plug distance is regulated by applying an electrical field over the capillary for a short period of time between each injection. After the final injection, the separation is completed by electrophoresis for a time period corresponding to that in the single‐injection mode.Keywords
This publication has 16 references indexed in Scilit:
- Quantitative determination of salbutamol in tablets by multiple-injection capillary zone electrophoresisJournal of Chromatography A, 2008
- Quantification of buserelin in a pharmaceutical product by multiple‐injection CZEElectrophoresis, 2007
- Partial filling multiple injection affinity capillary electrophoresis (PFMIACE) to estimate binding constants of receptors to ligandsTalanta, 2007
- Why not using capillary electrophoresis in drug analysis?Electrophoresis, 2006
- Recent advances in pharmaceutical applications of chiral capillary electrophoresisJournal of Pharmaceutical and Biomedical Analysis, 2006
- Multiple-injection affinity capillary electrophoresis to examine binding constants between glycopeptide antibiotics and peptidesJournal of Chromatography A, 2006
- Multiple injection techniques for microfluidic sample handlingElectrophoresis, 2003
- Analysis of Single-Strand Conformation Polymorphism by Capillary Electrophoresis with Laser-Induced Fluorescence Detection Using Short-Chain Polyacrylamide as Sieving MediumAnalytical Biochemistry, 1997
- Assessment of injection volume limits when using on-column focusing with microbore liquid chromatographyJournal of Chromatography A, 1997
- The use of a short-end injection procedure to achieve improved performance in capillary electrophoresisChromatographia, 1996