Abstract
The objective of this paper is to provide details of the design and response of a full-scale cold-formed steel (CFS)-framed building that was tested under a series of dynamic excitations during different phases of construction. The seismic response of complete buildings framed from CFS is essentially unexplored, although significant work on the behavior of CFS members and subsystems, particularly shear walls has been conducted. The experiments described herein are the first tests of a CFS-framed building designed to North American seismic standards. Seismic testing was conducted using the twin shake tables at the University at Buffalo through the U.S. National Science Foundation Network for Earthquake Engineering Simulation program. The project was conducted in two phases. In the first phase, the building specimen was constructed and tested with only the structural components in place: CFS shear walls sheathed with oriented strand board (OSB), CFS gravity walls (unsheathed), and CFS-framed floor a...

This publication has 20 references indexed in Scilit: