Postreconstruction Nonlocal Means Filtering of Whole-Body PET With an Anatomical Prior
- 26 November 2013
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 33 (3) , 636-650
Abstract
Positron emission tomography (PET) images usually suffer from poor signal-to-noise ratio (SNR) due to the high level of noise and low spatial resolution, which adversely affect its performance for lesion detection and quantification. The complementary information present in high-resolution anatomical images from multi-modality imaging systems could potentially be used to improve the ability to detect and/or quantify lesions. However, previous methods that use anatomical priors usually require matched organ/lesion boundaries. In this study, we investigated the use of anatomical information to suppress noise in PET images while preserving both quantitative accuracy and the amplitude of prominent signals that do not have corresponding boundaries on computerized tomography (CT). The proposed approach was realized through a postreconstruction filter based on the nonlocal means (NLM) filter, which reduces noise by computing the weighted average of voxels based on the similarity measurement between patches of voxels within the image. Anatomical knowledge obtained from CT was incorporated to constrain the similarity measurement within a subset of voxels. In contrast to other methods that use anatomical priors, the actual number of neighboring voxels and weights used for smoothing were determined from a robust measurement on PET images within the subset. Thus, the proposed approach can be robust to signal mismatches between PET and CT. A 3-D search scheme was also investigated for the volumetric PET/CT data. The proposed anatomically guided median nonlocal means filter (AMNLM) was first evaluated using a computer phantom and a physical phantom to simulate realistic but challenging situations where small lesions are located in homogeneous regions, which can be detected on PET but not on CT. The proposed method was further assessed with a clinical study of a patient with lung lesions. The performance of the proposed method was compared to Gaussian, edge-preserving bilateral and NLM filters, as well as median nonlocal means (MNLM) filtering without an anatomical prior. The proposed AMNLM method yielded improved lesion contrast and SNR compared with other methods even with imperfect anatomical knowledge, such as missing lesion boundaries and mismatched organ boundaries.Keywords
Funding Information
- Australian Research Council (DP0988166)
This publication has 40 references indexed in Scilit:
- Regularized image reconstruction with an anatomically adaptive prior for positron emission tomographyPhysics in Medicine & Biology, 2009
- Nonlocal means-based speckle filtering for ultrasound imagesIEEE Transactions on Image Processing, 2009
- Efficient Nonlocal Means for Denoising of Textural PatternsIEEE Transactions on Image Processing, 2008
- An Optimized Blockwise Nonlocal Means Denoising Filter for 3-D Magnetic Resonance ImagesIEEE Transactions on Medical Imaging, 2008
- Nonlocal Prior Bayesian Tomographic ReconstructionJournal of Mathematical Imaging and Vision, 2007
- Nonlocal Image and Movie DenoisingInternational Journal of Computer Vision, 2007
- A channelized Hotelling observer study of lesion detection in SPECT MAP reconstruction using anatomical priorsPhysics in Medicine & Biology, 2007
- A Non-Local Algorithm for Image Denoising2005
- A Review of Image Denoising Algorithms, with a New OneMultiscale Modeling & Simulation, 2005
- Bayesian reconstruction of PET images: methodology and performance analysisPhysics in Medicine & Biology, 1996