Abstract
A novel chemiluminescent immunoassay method based on gold nanoparticles was developed for the detection of microcystins (MCs). The immunoassay included three main steps: indirect competitive immunoreaction, oxidative dissolution of gold nanoparticles, and indirect determination for MCs with Au3+-catalysed luminol chemiluminesent system. The method has a wide working range (0.05–10 µg L−1, r 2 = 0.9914), the limit of detection was determined to be 0.024 µg L−1, which is much lower than the World Health Organization's proposed guidelines (1 µg L−1) for drinking-water. The proposed method was applied to MC analysis in natural water and fish tissue samples, and most results in the proposed method were in agreement with the conventional indirect competitive enzyme-linked immunosorbent assay method, which indicated that the new chemiluminescent immunoassay was sensitive, reliable, and suitable for MC analysis in natural water and fish tissue samples.

This publication has 32 references indexed in Scilit: