Effect of cooling and re-warming on cerebral and whole body electrical impedance
Authors:
- Barbara E LingwoodBLBarbara E Lingwood
- Kimble R DunsterKDKimble R Dunster
- Genevieve N HealyGHGenevieve N Healy
- Paul B ColditzPCPaul B Colditz
- 17 February 2004
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 25 (2) , 413-420
Abstract
Cerebral electrical impedance is useful for the detection of cerebral edema following hypoxia in newborn infants. Thus it may be useful for determining neurological outcome or monitoring treatment. Hypothermia is a promising new therapy currently undergoing trials, but will alter impedance measurements. This study aimed to define the relationship between temperature and both cerebral and whole body electrical impedance, and to derive correction factors for adjustment of impedance measurements during hypothermia. In eight anaesthetized 1-2 day old piglets rectal, tympanic and scalp temperatures were monitored continuously. Following baseline readings at a rectal temperature of 39 degrees C, piglets were cooled to 32 degrees C. Four piglets were re-warmed. Cerebral and whole body impedance were measured at each 0.5 degrees C as rectal temperature decreased. There was a strong linear relationship between both cerebral and whole body impedance and each of the temperatures measured. There was no difference in the relationship between impedance and rectal, tympanic or scalp temperatures. The relationship for impedance and rectal temperature was the same during cooling and re-warming. Using the correction factors derived it will be possible to accurately monitor cerebral and whole body fluid distribution during hypothermic treatment.Keywords
This publication has 10 references indexed in Scilit:
- Cerebral impedance and neurological outcome following a mild or severe hypoxic/ischemic episode in neonatal pigletsBrain Research, 2003
- Noninvasive measurement of cerebral bioimpedance for detection of cerebral edema in the neonatal pigletBrain Research, 2002
- Measurement of extracellular fluid volume in the neonate using multiple frequency bio-impedance analysisPhysiological Measurement, 2000
- Monitoring Temperature‐Induced Changes in Tissue during Hyperthermia by Impedance MethodsaAnnals of the New York Academy of Sciences, 1999
- Assessment of total body water using bioelectrical impedance analysis in neonates receiving intensive careArchives of Disease in Childhood - Fetal and Neonatal Edition, 1997
- MuIti‐frequency bioelectrical impedance augments the diagnosis and management of lymphoedema in post‐mastectomy patientsEuropean Journal of Clinical Investigation, 1992
- Bioelectrical Impedance Analysis For Measurement of Body Fluid VolumesJournal of Clinical Engineering, 1992
- The prediction of total body water using bioelectrical impedance in children and adolescentsAnnals of Human Biology, 1988
- Impedance of Skeletal Muscle from 1 Hz to 1 MHzIEEE Transactions on Biomedical Engineering, 1984
- Capacity and Conductivity of Body Tissues at Ultrahigh FrequenciesProceedings of the IRE, 1953