Fabry–Perot Beam Scanning Antenna for Remote Vital Sign Detection at 60 GHz
- 11 January 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 69 (6) , 3115-3124
Abstract
A beam scanning Fabry-Perot leaky-wave antenna (LWA) is designed at 60 GHz-band for single tone continuous-wave Doppler radar (DR)-based remote vital sign monitoring (RVSM) in a dynamic environment. A brief analysis is presented on antenna requirements for the DR in a typical dynamic scenario where a continuous RVSM is desired of a patient during sleep. The antenna is designed based on the drawn requirements with sufficiently high gain (>18 dBi) and wide beam scanning (12°) over the operating frequency band (62-65 GHz) for accurate RVSM up to 3 m distance. The patient under continuous health monitoring has a flexibility to change his/her position within 1 m angular distance from the fixed sensor position. Detailed RVSM measurements have been carried out with the proposed antenna system at 2 m and 3 m distances from the subject to verify the designed antenna's suitability for dynamic RVSM application. It has been shown that both the breathing rate (BR) and heartbeat rate (HR) can be successfully detected within 20° of the angular range by tuning the operating frequency from 62 to 65 GHz.Keywords
Funding Information
- Engineering and Physical Sciences Research Council (EP/P008380/1)
This publication has 21 references indexed in Scilit:
- Frequency selective surface antenna for remote vital sign monitoring with ultra-wide band doppler radarMicrowave and Optical Technology Letters, 2017
- Ultra-Wide Patch Antenna Array Design at 60 GHz Band for Remote Vital Sign Monitoring with Doppler Radar PrincipleJournal of Infrared, Millimeter, and Terahertz Waves, 2016
- Short-Range Noncontact Sensors for Healthcare and Other Emerging Applications: A ReviewSensors, 2016
- Monitoring vital signs using millimeter wave2016
- A phased array non-contact vital signs sensor with automatic beam steering2015
- Continuous non‐contact vital sign monitoring in neonatal intensive care unitHealthcare Technology Letters, 2014
- Microwave doppler radar for heartbeat detection vs electrocardiogramMicrowave and Optical Technology Letters, 2012
- Noncontact heart rate monitoring using Doppler radar and continuous wavelet transformMicrowave and Optical Technology Letters, 2011
- Non-contact respiratory rate measurement validation for hospitalized patients2009
- High gain planar antenna using optimised partially reflective surfacesIEE Proceedings - Microwaves, Antennas and Propagation, 2001