Motion corrected LV quantification based on 3D modelling for improved functional assessment in cardiac MRI
- 13 March 2015
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (7) , 2715-2733
Abstract
Cine MRI is a clinical reference standard for the quantitative assessment of cardiac function, but reproducibility is confounded by motion artefacts. We explore the feasibility of a motion corrected 3D left ventricle (LV) quantification method, incorporating multislice image registration into the 3D model reconstruction, to improve reproducibility of 3D LV functional quantification. Multi-breath-hold short-axis and radial long-axis images were acquired from 10 patients and 10 healthy subjects. The proposed framework reduced misalignment between slices to subpixel accuracy (2.88 to 1.21 mm), and improved interstudy reproducibility for 5 important clinical functional measures, i.e. end-diastolic volume, end-systolic volume, ejection fraction, myocardial mass and 3D-sphericity index, as reflected in a reduction in the sample size required to detect statistically significant cardiac changes: a reduction of 21–66%. Our investigation on the optimum registration parameters, including both cardiac time frames and number of long-axis (LA) slices, suggested that a single time frame is adequate for motion correction whereas integrating more LA slices can improve registration and model reconstruction accuracy for improved functional quantification especially on datasets with severe motion artefacts.Keywords
This publication has 38 references indexed in Scilit:
- Population-based studies of myocardial hypertrophy: high resolution cardiovascular magnetic resonance atlases improve statistical powerJournal of Cardiovascular Magnetic Resonance, 2014
- Nearly automated motion artifacts correction between multi breath-hold short-axis and long-axis cine CMR imagesComputers in Biology and Medicine, 2014
- Restoration of optimal ellipsoid left ventricular geometry: lessons learnt fromin silicosurgical modellingInteractive CardioVascular and Thoracic Surgery, 2013
- MRI-based motion correction of thoracic PET: initial comparison of acquisition protocols and correction strategies suitable for simultaneous PET/MRI systemsEuropean Radiology, 2011
- Estimation of tissue contractility from cardiac cine-MRI using a biomechanical heart modelBiomechanics and Modeling in Mechanobiology, 2011
- Automatic 3-D Breath-Hold Related Motion Correction of Dynamic Multislice MRIIEEE Transactions on Medical Imaging, 2010
- Correction of misaligned slices in multi-slice cardiovascular magnetic resonance using slice-to-volume registrationJournal of Cardiovascular Magnetic Resonance, 2008
- Reduction in Sample Size for Studies of Remodeling in Heart Failure by the Use of Cardiovascular Magnetic ResonanceJournal of Cardiovascular Magnetic Resonance, 2000
- Establishment and Performance of a Magnetic Resonance Cardiac Function ClinicJournal of Cardiovascular Magnetic Resonance, 2000
- On calculating with B-splinesJournal of Approximation Theory, 1972