Design of a porous biodegradable internal fixation for the treatment of pauwels type III femoral neck fractures
Open Access
- 31 October 2025
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 13, 1639459
Abstract
Prolonged internal fixation in the femur can cause issues like osteosclerosis and stress masking, which hinder fracture recovery. AZ31b magnesium alloy has already been widely investigated and shown to be biocompatible and biodegradable. This study used finite element analysis to investigate stress changes during healing, aiming to find the best time for removing internal fixation and focuses on optimizing the structural design of internal fixation, using AZ31b magnesium alloy, to address issues like osteosclerosis and stress shielding in femoral neck fracture healing. This study focuses on optimizing structural design for the treatment of Pauwels III femoral neck fractures using cannulated screws. Pauwels III fractures are characterized by high shear stress and unstable fracture angles, making them prone to fixation failure. By optimizing the fixation method, the risk of complications such as osteosclerosis and stress shielding can be mitigated, ultimately improving clinical outcomes. The findings show that when cancellous bone heals but cortical bone does not, stress on the fracture surface decreases. Early removal of titanium internal fixation, followed by biodegradable porous internal fixation, allows for natural degradation during healing. We simulated stress evolution across healing stages via finite element modeling to determine optimal fixation replacement timing. Four AZ31b magnesium alloy porous structures (cubic, honeycomb, diagonally orientated, modified truncated pyramid) were designed; their equivalent elastic modulus and strength were evaluated through simulated compression tests, while permeability was analyzed using computational fluid dynamics (CFD). We found that the cubic and honeycomb structures were found to have higher permeability (6.23 × 10 -7 m 2 , 1.636 × 10 -7 m 2 ) and have high elastic modulus (8.422Gpa, 14.694Gpa) which can match the elastic modulus of human bone. Optimal structures were then applied to an inverted triangular screw group model for biomechanical validation post-femoral neck fracture fixation. Finite element analysis of a Pauwels III femoral neck fracture model indicated that the honeycomb porous internal fixation had superior mechanical properties. In conclusion, this study proposed a solution to osteosclerosis and stress masking after femoral neck fracture surgery.Keywords
This publication has 34 references indexed in Scilit:
- Degradation products of magnesium implant synergistically enhance bone regeneration: Unraveling the roles of hydrogen gas and alkaline environmentBioactive Materials, 2025
- Microstructural, biocompatibility and mechanical investigation of MgHAp and AgHAp: Comparative reportJournal of Materials Science: Materials in Medicine, 2023
- Sequential release of vascular endothelial growth factor-A and bone morphogenetic protein-2 from osteogenic scaffolds assembled by PLGA microcapsules: A preliminary study in vitroInternational Journal of Biological Macromolecules, 2023
- Structural design and mechanical properties of porous structured diamond abrasive tool by selective laser meltingCeramics International, 2022
- Immunomodulatory bioactive glasses for tissue regenerationActa Biomaterialia, 2021
- Functional Biomaterials for Bone Regeneration: A Lesson in Complex BiologyAdvanced Functional Materials, 2020
- Topological design and additive manufacturing of porous metals for bone scaffolds and orthopaedic implants: A reviewBiomaterials, 2016
- Vascularized bone grafting fixed by biodegradable magnesium screw for treating osteonecrosis of the femoral headBiomaterials, 2016
- Trabecular bone adapts to long-term cyclic loading by increasing stiffness and normalization of dynamic morphometric ratesBone, 2013
- Finite element study of scaffold architecture design and culture conditions for tissue engineeringBiomaterials, 2009