Implementing dispersion measurement as part of scanning proton therapy commissioning and quality assurance
- 6 November 2023
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (22) , 225001
Abstract
Introduction. Dispersion in an accelerator quantifies the deviation of the proton trajectory when there is a momentum deviation. We present for the first time a safe method of measuring dispersion in the clinic, using a scintillator detector and the momentum deviations within a spill. This is an important accelerator quantity as we found that this is the reason behind the large dose fluctuation in our absolute dosimetry measurement. Methods. Dispersions are measured for nine energies in a Hitachi ProBeat system at three locations (isocenter and at two profile monitors) and at two gantry angles (0 and 90 degrees) by first measuring the spot position and momentum drift within a spill. The spot position drift is measured by the XRV-4000 at the isocenter, and by the two profile monitors located at 0.57 and 2.27 m from the isocenter. The momentum drift is calculated from the intra-spill range drift which is measured using the Ranger accessory. The dispersion at isocenter and its gradient are calculated using the weighted least square regression on the measured dispersions at the three locations. A constraint is formulated on the dispersion and its gradient to ensure minimal intra-spill spot position deviation around the isocenter. Results. The measured intra-spill range and spot positional drift at isocenter are less than 0.25 mm and 0.7 mm respectively. The momentum spread calculated from the range drift are less than 0.08%. The dispersion at the isocenter ranged from 0.50 to 4.30 m and the zero-crossing happens upstream of isocenter for all energies. 2 of the 9 energies (168.0 and 187.5 MeV) violated the constraint and has an intra-spill spot positional deviation greater than 1.0 within 5 cm from the isocenter. Conclusion. This measurement is recommended as part of commissioning and annual quality assurance for accelerator monitoring and to ensure intra-spill spot deviations remain low.Keywords
Funding Information
- Duke-NUS Oncology Academic Program Goh Foundation Proton Research Programme (08/FY2022/EX(SL)/125-A187)
This publication has 20 references indexed in Scilit:
- Comparative Effectiveness of Proton vs Photon Therapy as Part of Concurrent Chemoradiotherapy for Locally Advanced CancerJAMA Oncology, 2020
- Evaluation of dispersion functions derived from fluctuation of the bending magnetic field of a synchrotronNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2019
- Commissioning and beam characterization of the first gantry‐mounted accelerator pencil beam scanning proton systemMedical Physics, 2019
- AAPM task group 224: Comprehensive proton therapy machine quality assuranceMedical Physics, 2019
- Implication of spot position error on plan quality and patient safety in pencil‐beam‐scanning proton therapyMedical Physics, 2014
- Magnet Developments and Commissioning for the IBA Compact GantryIEEE Transactions on Applied Superconductivity, 2013
- Improvement of extraction efficiency from a compact synchrotron for proton beam therapy by applying particle tracking analysisAIP Conference Proceedings, 2013
- Comparison of therapeutic dosimetric data from passively scattered proton and photon craniospinal irradiations for medulloblastomaRadiation Oncology, 2012
- Design of a superconducting rotating gantry for heavy-ion therapyPhysical Review Special Topics - Accelerators and Beams, 2012
- A Treatment Planning Comparison of Passive-Scattering and Intensity-Modulated Proton Therapy for Typical Tumor SitesJournal of Radiation Research, 2012