Quantification of paravalvular leaks associated with TAVI implants using 4D MRI in an aortic root phantom made possible by the use of 3D printing
Authors:
Open Access
- 19 January 2023
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 10, 1083300
Abstract
Introduction: Transcatheter aortic valve implantation (TAVI) has become an alternative to surgical replacement of the aortic valve elderly patients. However, TAVI patients may suffer from paravalvular leaks (PVL). Detecting and grading is usually done by echocardiography, but is limited by resolution, 2D visualization and operator dependency. 4D flow magnetic resonance imaging (MRI) is a promising alternative, which did not reach clinical application in TAVI patients. The aim of this study was applying 3D printing technologies in order to evaluate flow patterns and hemodynamics of PVLs following TAVI, exploiting 4D flow MRI and standard ultrasound.Materials and methods: An MR-compatible, anatomically left ventricle, aortic root, and ascending aorta model was fabricated by combining 3D-printed parts and various soft silicone materials to match physiological characteristics. An Abbott Portico™ valve was used in continuous antegrade flow (12–22 l/min), retrograde flow with varying transvalvular pressures (60–110 mmHg), and physiological pulsatile hemodynamics (aortic pressure: 120/80 mmHg, cardiac output: 5 l/min) Time-resolved MR measurements were performed above and below the TAVI stent and compared with color Doppler ultrasound measurements in exactly the same setup.Results: The continuous antegrade flow measurements from MRI largely agreed with the flowmeter measurements, and a maximum error of only 7% was observed. In the retrograde configuration, visualization of the paravalvular leaks was possible from the MR measurements, but flow was overestimated by up to 33%. The 4D MRI measurement in the pulsatile setup revealed a single main PVL, which was also confirmed by the color Doppler measurements, and velocities were similar (2.0 m/s vs. 1.7 m/s).Discussion: 4D MRI techniques were used to qualitatively assess flow in a patient-specific, MR-compatible and flexible model, which only became possible through the use of 3D printing techniques. Flow patterns in the ascending aorta, identification and quantification of PVLs was possible and the location and extent of PVLs were confirmed by ultrasound measurements. The 4D MRI flow technique allowed evaluation of flow patterns in the ascending aorta and the left ventricle below the TAVI stent with good results in identifying PVLs, demonstrating its capabilities over ultrasound by providing the ability to visualize the paravalvular jets in three dimensions at however, additional expenditure of time and money.Keywords
This publication has 32 references indexed in Scilit:
- Assessment of Paravalvular Regurgitation Following TAVRJACC: Cardiovascular Imaging, 2015
- In vitro assessment of the influence of aortic annulus ovality on the hydrodynamic performance of self-expanding transcatheter heart valve prosthesesJournal of Biomechanics, 2014
- Incidence, Predictors, and Outcomes of Aortic Regurgitation After Transcatheter Aortic Valve ReplacementJACC, 2013
- Paravalvular leaks: mechanisms, diagnosis and managementEuroIntervention, 2012
- Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve ReplacementNew England Journal of Medicine, 2012
- The arterial WindkesselMedical & Biological Engineering & Computing, 2008
- Nature Optimizes the Swirling Flow in the Human Left VentriclePhysical Review Letters, 2005
- Systemic Arterial Compliance and Diastolic Runoff in Essential HypertensionAngiology, 1981
- Clinical Application of the Ellipsoid Left Heart Assist DeviceArtificial Organs, 1978
- Viscosity of Glycerol and Its Aqueous SolutionsIndustrial & Engineering Chemistry, 1951