Capillary refill time and cardiac output in children undergoing cardiac catheterization *
Authors:
- Anna-Theresa LobosALAnna-Theresa Lobos
- Suzie LeeSLSuzie Lee
- Kusum MenonKMKusum Menon
- 1 March 2012
- journal article
- Published by Wolters Kluwer Health in Pediatric Critical Care Medicine
- Vol. 13 (2) , 136-140
Abstract
Many pediatric healthcare providers believe that capillary refill time is a measure of perfusion and cardiac output in children. Despite its widespread use, there are no studies examining the relationship of capillary refill time to cardiac output in noncritically ill children. This study examined the inter-rater reliability of capillary refill time and its relationship to hemoglobin and with cardiac output in pediatric patients undergoing cardiac catheterization. Prospective observational study. Tertiary care pediatric hospital. A total of 58 children, ages 0.3-17 yrs, with congenital heart disease undergoing cardiac catheterization. Two clinicians performed two measurements of capillary refill time in a standardized fashion on 58 children undergoing cardiac catheterization. Cardiac output was determined by the Fick method within 15 mins of the first assessment of capillary refill time (time 1). Capillary refill time and cardiac output measurements were obtained in 44 children, and 108 paired measurements of capillary refill time were obtained to assess inter-rater reliability. The mean capillary refill time was 1.2 secs (±0.5 secs), and the mean cardiac output was 3.6 L/min/m (2.2-5.7 L/min/m). The inter-rater intraclass correlation coefficient was 0.12 (time 1) (95% confidence interval -0.15 to +0.37) and was 0.32 (95% confidence interval 0.058-0.54) at the end of the catheterization (time 2). A significant association was noted between average capillary refill time at time 1 and hemoglobin, with higher hemoglobin correlating with longer capillary refill time (p = .015). There was no significant correlation between the average capillary refill time taken at the time of cardiac output measurement (time 1) and measured cardiac output (r = .331, 95% confidence interval for r, .066-.552). We found that the inter-rater reliability of capillary refill time was poor and variable under controlled conditions and capillary refill time was not correlated with cardiac output in anesthetized nonacutely ill pediatric patients undergoing cardiac catheterization. Caution should be used in inferring cardiac output from capillary refill time measurements alone.Keywords
This publication has 13 references indexed in Scilit:
- A multidisciplinary survey on capillary refill time: Inconsistent performance and interpretation of a common clinical testPediatric Critical Care Medicine, 2008
- Capillary refill time in adultsEmergency Medicine Journal, 2008
- Capillary refill: prognostic value in Kenyan childrenArchives of Disease in Childhood, 2004
- Is This Child Dehydrated?JAMA, 2004
- Management of septic shock in the pediatric emergency department in 2004Clinical Pediatric Emergency Medicine, 2004
- Clinical detection of low upper body blood flow in very premature infants using blood pressure, capillary refill time, and central-peripheral temperature differenceArchives of Disease in Childhood - Fetal and Neonatal Edition, 2004
- Clinical practice parameters for hemodynamic support of pediatric and neonatal patients in septic shock*Critical Care Medicine, 2002
- Capillary refill and core-peripheral temperature gap as indicators of haemodynamic status in paediatric intensive care patientsArchives of Disease in Childhood, 1999
- Effects of neonatal polycythemia and hemodilution on capillary perfusionThe Journal of Pediatrics, 1992
- Defining normal capillary refill: Variation with age, sex, and temperatureAnnals of Emergency Medicine, 1988