Microbiological quality of drinking water from dispensers in Italy
Open Access
- 26 January 2010
- journal article
- Published by Springer Nature in BMC Microbiology
- Vol. 10 (1) , 19
Abstract
Background: Water coolers are popular in office buildings and commercial stores and the quality of this source of drinking water has the potential to cause waterborne outbreaks, especially in sensitive and immunocompromised subjects. The aim of this study was to determine the quality of water plumbed in coolers from commercial stores in comparison with tap water in Italy. Methods: For each sample, microbial parameters and chemical indicators of contamination were evaluated and information about the date of installation, time since last ordinary and extraordinary maintenance of water coolers was collected. Results: In all samples the chemical parameters (nitrite, ammonium, free active chlorine residual) did not exceed the reference values of the drinking water regulation; the pH value in 86.8% samples of the carbonated waters was lower than the reference limit. The microbiological results indicated that the bacteria count at 22°C and 37°C was higher than the required values in 71% and 81% for the non-carbonated water and in 86% and 88% for the carbonated one, respectively. Enterococcus spp. and Escherichia coli were not detected in any of the water samples. Pseudomonas aeruginosa was found in only one sample of the tap water and in 28.9% and 23.7% of the non-carbonated and carbonated water samples, respectively. No statistically significant differences in bacterial counts at 22°C and 37°C have been found between the non-carbonated and carbonated water from the sampled coolers in relation with the time since the last filter was substituted. The bacteriological quality of tap water was superior to that of non-carbonated and carbonated water from coolers. Conclusion: The results emphasize the importance of adopting appropriate routinely monitoring system in order to prevent or to diminish the chances of contamination of this water source.Keywords
This publication has 11 references indexed in Scilit:
- Control of Pseudomonas aeruginosa and Stenotrophomonas maltophilia contamination of microfiltered water dispensers with peracetic acid and hydrogen peroxideInternational Journal of Food Microbiology, 2009
- Control of bacterial contamination in microfiltered water dispensers (MWDs) by disinfectionInternational Journal of Food Microbiology, 2009
- Risk of Waterborne Illness Via Drinking Water in the United States2008
- Drinking water consumption patterns in British Columbia: An investigation of associations with demographic factors and acute gastrointestinal illnessScience of The Total Environment, 2007
- Published Case Studies of Waterborne Disease Outbreaks—Evidence of a Recurrent ThreatWater Environment Research, 2007
- A Waterborne Outbreak of Gastroenteritis with Multiple Etiologies among Resort Island Visitors and Residents: Ohio, 2004Clinical Infectious Diseases, 2007
- Tracking Patterns of Enteric Illnesses in Populations and CommunitiesEnvironmental Health Perspectives, 2007
- Bacteriological Quality of Drinking Water from Dispensers (Coolers) and Possible Control MeasuresJournal of Food Protection, 2006
- Incidence and Epidemiology of Irritable Bowel Syndrome After a Large Waterborne Outbreak of Bacterial DysenteryGastroenterology, 2006
- Comparison of the microbiological quality of water coolers and that of municipal water systemsApplied and Environmental Microbiology, 1994