Combined photoplethysmographic monitoring of respiration rate and pulse: a comparison between different measurement sites in spontaneously breathing subjects
Authors:
- 15 August 2007
- journal article
- research article
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 51 (9) , 1250-1257
Abstract
Background: The non‐invasive photoplethysmographic (PPG) signal reflects blood flow and volume in a tissue. The PPG signal shows variation synchronous with heartbeat (PPGc), as used in pulse oximetry, and variations synchronous with breathing (PPGr). PPGr has been used for non‐invasive monitoring of respiration with promising results. Our aim was to investigate PPG signals recorded from different skin sites in order to find suitable locations for parallel monitoring of variations synchronous with heartbeat and breathing.Methods: PPG sensors were applied to the forearm, finger, forehead, wrist and shoulder on 48 awake healthy volunteers. From these sites, seven PPG signals were simultaneously recorded during normal spontaneous breathing over 10 min. Capnometry served as respiration and electrocardiogram (ECG) as pulse reference signals. PPG signals were compared with respect to power spectral content and squared coherence.Results: Forearm PPG measurement showed significantly higher power within the respiratory region of the power spectrum [median (quartile range) 42 (26)%], but significantly lower power within the cardiac region [9 (10)%] compared with the other skin sites. PPG finger measurement showed the opposite; in transmission mode, the power within the respiratory region was significantly lower [4 (10)%] and within the cardiac region significantly higher [45 (25)%] than the other sites. PPGc coherence values were generally high [>0.96 (0.08)], and PPGr coherence values lower [0.83 (0.35)–0.94 (0.17)].Conclusion: Combined PPG respiration and pulse monitoring is possible, but there are significant differences between the respiratory and cardiac components of the PPG signal at different sites.Keywords
This publication has 27 references indexed in Scilit:
- What Is the Best Site for Measuring the Effect of Ventilation on the Pulse Oximeter Waveform?Anesthesia & Analgesia, 2006
- Pulse oximetry in the oesophagusPhysiological Measurement, 2005
- Contactless Multiple Wavelength Photoplethysmographic Imaging: A First Step Toward “SpO2 Camera” TechnologyAnnals of Biomedical Engineering, 2005
- Respiration can be monitored by photoplethysmography with high sensitivity and specificity regardless of anaesthesia and ventilatory modeActa Anaesthesiologica Scandinavica, 2005
- Non‐invasive monitoring of muscle blood perfusion by photoplethysmography: evaluation of a new applicationActa Physiologica Scandinavica, 2005
- Influence of Sensor Site Location on Pulse Oximetry Kinetics in ChildrenAnesthesia & Analgesia, 1993
- Randomized Evaluation of Pulse Oximetry in 20,802 Patients; IIAnesthesiology, 1993
- A search for arteriovenous anastomoses in human skin using ultrasound DopplerActa Physiologica Scandinavica, 1993
- Pulse OximetryAnesthesiology, 1989
- Basal Perfusion of the Cutaneous Microcirculation: Measurements as a Function of Anatomic PositionJournal of Investigative Dermatology, 1983