Liquid-phase microextraction and gas-chromatographic determination of selenium(IV) in aqueous samples

Authors:

Abstract
A liquid-phase microextraction (LPME) method was employed for preconcentration of selenium as piazselenol complex in aqueous samples. The samples reacted with o-phenylenediamine in 0.1 M HCl at 90°C for 15 min, and then LPME was performed. A microdrop of carbon tetrachloride was applied as the extracting solvent. After extraction, the microdrop was introduced directly into the injection port of gas chromatography for analysis. Several important extraction parameters such as the type of organic solvent, sample and organic drop volumes, salt concentration, stirring rate, and exposure time were controlled and optimized. In the proposed LPME, the extraction was achieved by suspending a 3 µL carbon tetrachloride drop from the tip of a microsyringe immersed in 12.5 mL of aqueous solution. Under optimized conditions, a dynamic linear range was obtained in the range of 20–1000 µg L−1. The preconcentration factor and the limit of detection of selenium in this method were 91 and 0.9 µg L−1, respectively. The optimized procedure was successfully applied to the extraction and determination of selenium in different types of real samples. The relative standard deviations for the spiking levels of 50–100 µg L−1 in the real samples were in the range of 3.2–6.1%, and the relative errors were located in the range of −5.4 to 5%.