Coronary vessel visualization using true 16-row multi-slice computed tomography technology
- 1 April 2005
- journal article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 21 (2-3) , 331-337
Abstract
Background :Multi-slice computed tomography (MSCT) scanners with retrospective ECG-gating permit visualization of the coronary arteries. Limited spatial and temporal resolution as well as breathing artefacts due to the scan time can cause poor distal vessel segment and side branch visualization. The latest MSCT generation with true 16-detector slices (Sensation 16 ®, Siemens, Forchheim, Germany) provides furthermore improved temporal and spatial resolution, as well as significantly reduced scan time. To assess, whether this technical improvement has also an impact on image quality we conducted the following study. Methods and material :Sixty-two consecutive patients (33 male, 29 female, mean age 63±8 [47–79] years, heart rate after β-blockade 63±7 [45–86] bpm) with suspicion of coronary artery disease (CAD) were examined by cardiac MSCT. Parameter settings were: 0.75mm collimation, 2.8mm table feed/rotation, caudocranial scan direction, 80cc contrast media biphasic injection protocol, gantry rotation time 375ms, temporal resolution 188ms). Thirteen coronary segments (sgts) were evaluated in each patient (total number: 806sgts). Image quality of each segment was determined as: excellent – free of motion artefacts, good – mild motion artefacts, relevant artefacts – still diagnostic value, severe calcification and insufficient image quality – not visualized segment. Results :301/806 (37%) sgts showed excellent and 294/806 (36%) sgts good image quality. Relevant artefacts were seen in 107/806 (13%) sgts, calcifications in 41/806 (5%) sgts. 63/806 (8%) sgts could not be visualized (34 of them (54%) either segment 9 or 10). Diagnostic image quality was achieved in 702/806 (87%) sgts. Conclusions :Due to true 16-slice technology and faster gantry rotation time MSCT image quality could be improved and allows a visualization of the entire coronary tree. Larger, randomized, catheter-controlled studies have to be conducted to determine, whether this improved visualization also translates into better diagnostic accuracy.Keywords
This publication has 16 references indexed in Scilit:
- Detection of coronary stenoses by multidetector computed tomography: it's all about resolutionJACC, 2004
- Diagnostic accuracy of multidetector computed tomography coronary angiography in patients with angiographically proven coronary artery diseaseJACC, 2004
- Detection of Coronary Artery Stenoses With Thin-Slice Multi-Detector Row Spiral Computed Tomography and Multiplanar ReconstructionCirculation, 2003
- Image Quality in a Standardized Algorithm for Minimally Invasive Coronary Angiography with Multislice Spiral Computed TomographyJournal of Computer Assisted Tomography, 2003
- Reliable Noninvasive Coronary Angiography With Fast Submillimeter Multislice Spiral Computed TomographyCirculation, 2002
- Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomographyClinical Imaging, 2002
- Non-invasive characterisation of coronary lesion morphology and composition by multislice CT: first results in comparison with intracoronary ultrasoundEuropean Radiology, 2001
- Noninvasive detection of coronary lesions by multislice computed tomography: Results of the new age pilot trialCatheterization and Cardiovascular Interventions, 2001
- Non-invasive characterisation of coronary lesion morphology by multi-slice computed tomography: a promising new technology for risk stratification of patients with coronary artery diseaseHeart, 2001
- Multidetector CT des Herzens: Erste Klinische Anwendung einer retrospektiv EKG-gesteuerten Spirale mit optimierter zeitlicher und örtlicher Auflösung zur Darstellung der HerzkranzgefäßeRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2000