Can A Novel Rectangular Footplate Provide Higher Resistance to Subsidence Than Circular Footplates? An Ex Vivo Biomechanical Study
Authors:
- Murat PekmezciMPMurat Pekmezci
- Erik McDonaldEMErik McDonald
- Abbey KennedyAKAbbey Kennedy
- Russell DediniRDRussell Dedini
- Trigg McClellanTMTrigg McClellan
- Christopher AmesCAChristopher Ames
- Vedat DevirenVDVedat Deviren
- 1 September 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Spine
- Vol. 37 (19) , E1177-E1181
Abstract
Ex vivo biomechanical evaluation using cadaveric vertebral bodies. To compare the subsidence characteristics of a novel rectangular footplate design with a conventional circular footplate design. Cage subsidence is a postoperative complication after reconstruction of corpectomy defects in the thoracolumbar spine and depends on factors, such as bone quality, adjunctive fixation, and the relationship between the footplate on the cage and the vertebral body endplate. Twenty-four cadaveric vertebrae (T12–L5) were disarticulated, potted in a commercial resin, loaded with either a circular or a rectangular footplate, and tested in a servo hydraulic testing machine. Twelve vertebral bodies were loaded with a circular footplate, and after subsidence the same vertebral bodies were loaded with a rectangular footplate. The second set of 12 vertebral bodies was loaded with a rectangular footplate only. Force-displacement curves were developed for the 3 groups, and the ultimate load to failure and stiffness values were calculated. The ultimate load to failure with the circular footplate was 1310 N (SD, 482). The ultimate load to failure with a rectangular footplate with a central defect and without a central defect was 1636 N (SD, 513) and 2481 N (SD, 1191), respectively. The stiffness of the constructs with circular footplate was 473 N/mm (SD, 205). The stiffness of the constructs with a rectangular footplate with a central defect and without a central defect was 754 N/mm (SD, 217) and 1054 N/mm (SD, 329), respectively. A rectangular footplate design is more resistant to subsidence than a circular footplate design in an ex vivo biomechanical model. The new design had higher load to failure even in the presence of a central defect. These findings suggest that rectangular footplates may provide better subsidence resistance when used to reconstruct defects after thoracolumbar corpectomy.Keywords
This publication has 9 references indexed in Scilit:
- The Strength Profile of the Thoracolumbar Endplate Reflects the Sagittal Contours of the SpineSpine, 2011
- Minimally Invasive Surgery for Traumatic Spinal PathologiesSpine, 2010
- The effect of implant size and device keel on vertebral compression properties in lumbar total disc replacementThe Spine Journal, 2010
- A new distractable implant for vertebral body replacement: biomechanical testing of four implants for the thoracolumbar spineArchives of orthopaedic and trauma surgery, 2009
- VERTEBRAL BODY REPLACEMENT SYSTEMS WITH EXPANDABLE CAGES IN THE TREATMENT OF VARIOUS SPINAL PATHOLOGIESNeurosurgery, 2008
- Adjacent-level vertebral body fractures after expandable cage reconstructionJournal of Neurosurgery: Spine, 2008
- Corpectomy followed by the placement of instrumentation with titanium cages and recombinant human bone morphogenetic protein–2 for vertebral osteomyelitisJournal of Neurosurgery: Spine, 2007
- Anterior expandable strut cage replacement for osteoporotic thoracolumbar vertebral collapseJournal of Neurosurgery: Spine, 2006
- Cages: designs and conceptsEuropean Spine Journal, 2000