Segmentation of the Aorta and Pulmonary Arteries Based on 4D Flow MRI in the Pediatric Setting Using Fully Automated Multi‐Site, Multi‐Vendor, and Multi‐Label Dense U‐Net
- 18 November 2021
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 55 (6) , 1666-1680
Abstract
Background: Automated segmentation using convolutional neural networks (CNNs) have been developed using four‐dimensional (4D) flow magnetic resonance imaging (MRI). To broaden usability for congenital heart disease (CHD), training with multi‐institution data is necessary. However, the performance impact of heterogeneous multi‐site and multi‐vendor data on CNNs is unclear.Purpose: To investigate multi‐site CNN segmentation of 4D flow MRI for pediatric blood flow measurement.Study Type: Retrospective.Population: A total of 174 subjects across two sites (female: 46%; N = 38 healthy controls, N = 136 CHD patients). Participants from site 1 (N = 100), site 2 (N = 74), and both sites (N = 174) were divided into subgroups to conduct 10‐fold cross validation (10% for testing, 90% for training).Field Strength/Sequence: 3 T/1.5 T; retrospectively gated gradient recalled echo‐based 4D flow MRI.Assessment: Accuracy of the 3D CNN segmentations trained on data from single site (single‐site CNNs) and data across both sites (multi‐site CNN) were evaluated by geometrical similarity (Dice score, human segmentation as ground truth) and net flow quantification at the ascending aorta (Qs), main pulmonary artery (Qp), and their balance (Qp/Qs), between human observers, single‐site and multi‐site CNNs.Statistical Tests: Kruskal–Wallis test, Wilcoxon rank‐sum test, and Bland–Altman analysis. A P‐value P = 0.55; site 2: 0.906 vs. 0.904, P = 0.69) and for the pulmonary arteries (site 1: 0.894 vs. 0.895, P = 0.64; site 2: 0.870 vs. 0.869, P = 0.96). Qs site‐1 medians were 51.0–51.3 mL/cycle (P = 0.81) and site‐2 medians were 66.7–69.4 mL/cycle (P = 0.84). Qp site‐1 medians were 46.8–48.0 mL/cycle (P = 0.97) and site‐2 medians were 76.0–77.4 mL/cycle (P = 0.98). Qp/Qs site‐1 medians were 0.87–0.88 (P = 0.97) and site‐2 medians were 1.01–1.03 (P = 0.43). Bland–Altman analysis for flow quantification found equivalent performance.Data Conclusion: Multi‐site CNN‐based segmentation and blood flow measurement are feasible for pediatric 4D flow MRI and maintain performance of single‐site CNNs.Level of Evidence: 3Technical Efficacy: Stage 2Keywords
Funding Information
- National Heart, Lung, and Blood Institute (R01HL115828, R01HL133504)
This publication has 23 references indexed in Scilit:
- Assessment of intracardiac flow and vorticity in the right heart of patients after repair of tetralogy of Fallot by flow-sensitive 4D MRIEuropean Radiology, 2016
- U-Net: Convolutional Networks for Biomedical Image Segmentation2015
- Metrics for evaluating 3D medical image segmentation: analysis, selection, and toolBMC Medical Imaging, 2015
- Congenital heart disease assessment with 4D flow MRIJournal of Magnetic Resonance Imaging, 2015
- Atlas-based analysis of 4D flow CMR: Automated vessel segmentation and flow quantificationJournal of Cardiovascular Magnetic Resonance, 2015
- Understanding Bland Altman analysisBiochemia Medica, 2015
- 4D flow magnetic resonance imaging in bicuspid aortic valve disease demonstrates altered distribution of aortic blood flow helicityMagnetic Resonance in Medicine, 2013
- Anatomical and pathophysiological classification of congenital heart diseaseCardiovascular Pathology, 2010
- Normal values for aortic diameters in children and adolescents – assessment in vivo by contrast-enhanced CMR-angiographyJournal of Cardiovascular Magnetic Resonance, 2008
- Multisite validation of image analysis methods: assessing intra- and intersite variability2002