Time-gated Förster resonance energy transfer (TG-FRET) between Tb complexes and luminescent semiconductor quantum dots (QDs) provides highly advantageous photophysical properties for multiplexed biosensing. Multiplexed Tb-to-QD FRET immunoassays possess a large potential for in vitro diagnostics, but their performance is often insufficient for their application under clinical conditions. Here, we developed a homogeneous TG-FRET immunoassay for the quantification of carcinoembryonic antigen (CEA), neuron-specific enolase (NSE), and prostate-specific antigen (PSA) from a single serum sample by multiplexed Tb-to-QD FRET. Tb–IgG antibody donor conjugates were combined with compact QD-F(ab’)2 antibody acceptor conjugates with three different QDs emitting at 605, 650, and 705 nm. Upon antibody–antigen–antibody sandwich complex formation, the QD acceptors were sensitized via FRET from Tb, and the FRET ratios of QD and Tb TG luminescence intensities increased specifically with increasing antigen concentrations. Although limits of detection (LoDs: 3.6 ng/mL CEA, 3.5 ng/mL NSE, and 0.3 ng/mL PSA) for the triplexed assay were slightly higher compared to the single-antigen assays, they were still in a clinically relevant concentration range and could be quantified in 50 µL serum samples on a B·R·A·H·M·S KRYPTOR Compact PLUS clinical immunoassay plate reader. The simultaneous quantification of CEA, NSE, and PSA at different concentrations from the same serum sample demonstrated actual multiplexing Tb-to-QD FRET immunoassays and the potential of this technology for translation into clinical diagnostics.Keywords
Funding Information
- Agence Nationale de la Recherche (ANR project “Neutrinos” and Labex “SynOrg”)
- Institut Universitaire de France (Membership Niko Hildebrandt)
- Région Normandie (Chaire d'Excellence COBRA-FRET)
- Horizon 2020 Framework Programme (Marie Sklodowska-Curie grant agreement No. 846764)
This publication has 50 references indexed in Scilit:
- Quantum-Dot-Based Förster Resonance Energy Transfer Immunoassay for Sensitive Clinical Diagnostics of Low-Volume Serum SamplesACS Nano, 2013
- Six-Color Time-Resolved Förster Resonance Energy Transfer for Ultrasensitive Multiplexed BiosensingJournal of the American Chemical Society, 2012
- A Review on the Clinical Utility of PSA in Cancer ProstateIndian Journal of Surgical Oncology, 2012
- Octadentate Cages of Tb(III) 2-Hydroxyisophthalamides: A New Standard for Luminescent Lanthanide LabelsJournal of the American Chemical Society, 2011
- Reactive Semiconductor Nanocrystals for Chemoselective Biolabeling and Multiplexed AnalysisACS Nano, 2011
- Quantum Dot Biosensors for Ultrasensitive Multiplexed DiagnosticsAngewandte Chemie International Edition, 2010
- Mucins CA 125, CA 19.9, CA 15.3 and TAG-72.3 as Tumor Markers in Patients with Lung Cancer: Comparison with CYFRA 21-1, CEA, SCC and NSETumor Biology, 2008
- Taking advantage of luminescent lanthanide ionsChemical Society Reviews, 2005
- Tumor Markers (CEA, CA 125, CYFRA 21-1, SCC and NSE) in Patients with Non-Small Cell Lung Cancer as an Aid in Histological Diagnosis and PrognosisTumor Biology, 2003
- ANTENNA EFFECT IN LUMINESCENT LANTHANIDE CRYPTATES: A PHOTOPHYSICAL STUDYPhotochemistry and Photobiology, 1990