Comparison of the effect of membrane sizes and fibre arrangements of two membrane oxygenators on the inflammatory response, oxygenation and decarboxylation in a rat model of extracorporeal membrane oxygenation
Authors:
Open Access
- 15 June 2020
- journal article
- research article
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 20 (1) , 1-8
Abstract
Background: Extracorporeal membrane oxygenation (ECMO) has gained widespread acceptance for the treatment of critically ill patients suffering from cardiac and/or respiratory failure. Various animal models have been developed to investigate the adverse effects induced by ECMO. Different membrane oxygenators have been used with varying priming volumes and membrane surfaces (Micro-1, small animal membrane oxygenator (SAMO)). Methods: Sixteen male Lewis rats (350–400 g) were randomly assigned to receive ECMO with Micro-1 or SAMO (n = 8, respectively). Venoarterial ECMO was established after cannulation of the femoral artery and the jugular vein. The cardiac output was measured using a left-ventricular conductance catheter. The oxygen fraction of the ECMO was set to 1.0, 0.75, 0.5 and 0.21 after a stabilisation period of 15 min. Further, arterial blood gas analyses were performed at baseline, and during the first hour every 15 min after commencing the ECMO, and subsequently every 30 min. Dilutional anaemia was calculated using haemoglobin concentration at baseline, and 15 min after the start of ECMO therapy. Moreover, inflammation was determined by measuring tumour necrosis factor alpha, interleukin-6 and -10 at baseline and every 30 min. Results: Animals of the Micro-1 group showed a significantly lower dilutional anaemia (ΔHaemoglobin t0 – t0.25: SAMO 6.3 [5.6–7.5] g/dl vs. Micro-1 5.6 [4.6–5.8] g/dl; p = 0.028). Further, significantly higher oxygen partial pressure was measured in the SAMO group, at an oxygen fraction of 0.75, 0.5 and 0.21 (380 [356–388] vs. 314 [263–352] mmHg, p = 0.002; 267 [249–273] mmHg vs. 197 [140–222] mmHg, p = 0.002; 87 [82–106] mmHg vs. 76 [60–79] mmHg, p = 0.021, respectively). However, no differences were found regarding the oxygen fraction of 1.0, in terms of carbon-dioxide partial pressure and cardiac output. Moreover, in the Micro-1 group tumour necrosis factor alpha was increased after 60 min and interleukin-6 after 120 min. Conclusion: While the dilutional anaemia was increased after commencing the ECMO, the oxygenation was augmented in the SAMO group. The inflammatory response was elevated in the Micro-1 group.Keywords
Funding Information
- Von-Behring-Röntgen-Stiftung (67-0007)
This publication has 18 references indexed in Scilit:
- Inactivated antithombin as anticoagulant reversal in a rat model of cardiopulmonary bypass: a potent and potentially safer alternative to protamineBritish Journal of Haematology, 2018
- Extracorporeal Life Support Increases Survival After Prolonged Ventricular Fibrillation Cardiac Arrest in the RatShock, 2017
- α7 nicotinic acetylcholine receptor agonist attenuates the cerebral injury in a rat model of cardiopulmonary bypass by activating the Akt/GSK3β pathwayMolecular Medicine Reports, 2017
- The inflammatory response to extracorporeal membrane oxygenation (ECMO): a review of the pathophysiologyCritical Care, 2016
- Role of the Toll-like receptor 3 signaling pathway in the neuroprotective effect of sevoflurane pre-conditioning during cardiopulmonary bypass in ratsMolecular Medicine Reports, 2015
- An experimental model of myocardial infarction and controlled reperfusion using a miniaturized cardiopulmonary bypass in ratsInteractive CardioVascular and Thoracic Surgery, 2014
- Animal Models of Cardiopulmonary Bypass: Development, Applications, and ImpactSeminars in Cardiothoracic and Vascular Anesthesia, 2010
- A rat model of cardiopulmonary bypass with excellent survivalJournal of Surgical Research, 2005
- A literature review of cardiopulmonary bypass models for ratsPerfusion, 1999
- Instrumental Responses in Rats After Hypothermic Cardiopulmonary By-Pass.Experimental Biology and Medicine, 1967