Landing gear structure is developed predominantly using safe life design criteria. Health monitoring and structural prognosis techniques for landing gear cannot focus on crack detection; techniques for determining input loads and calculating damage or methods for directly measuring material damage must be employed. This paper will discuss Messier-Dowty’s research into structural monitoring over the past several years. Principally, direct damage detection systems and load monitoring systems will be discussed.