Overview of double dosimetry procedures for the determination of the effective dose to the interventional radiology staff
- 18 February 2008
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 129 (1-3) , 333-339
Abstract
In interventional radiology, for an accurate determination of effective dose to the staff, measurements with two dosemeters have been recommended, one located above and one under the protective apron. Such ‘double dosimetry’ practices and the algorithms used for the determination of effective dose were reviewed in this study by circulating a questionnaire and by an extensive literature search. The results indicated that regulations for double dosimetry almost do not exist and there is no firm consensus on the most suitable calculation algorithms. The calculation of effective dose is mainly based on the single dosemeter measurements, in which either personal dose equivalent, directly, (dosemeter below the apron) or a fraction of personal dose equivalent (dosemeter above the apron) is taken as an assessment of effective dose. The most recent studies suggest that there might not be just one double dosimetry algorithm that would be optimum for all interventional radiology procedures. Further investigations in several critical configurations of interventional radiology procedures are needed to assess the suitability of the proposed algorithms.Keywords
This publication has 14 references indexed in Scilit:
- Double-dosimetry algorithm for workers in interventional radiologyRadiation Protection Dosimetry, 2008
- Monte Carlo simulations of occupational radiation doses in interventional radiologyBritish Journal of Radiology, 2007
- Estimating effective dose for a cardiac catheterisation procedure with single or double personal dosemetersRadiation Protection Dosimetry, 2006
- ESTIMATION OF THE EFFECTIVE DOSE WHEN PROTECTIVE APRONS ARE USED IN MEDICAL PROCEDURES: A THEORETICAL EVALUATION OF SEVERAL METHODSHealth Physics, 2002
- Dosimetry of Occupationally Exposed Persons in Diagnostic and Interventional Arteriography. Part 2: Assessment of Effective DoseRadiation Protection Dosimetry, 1999
- The Estimation of Occupational Effective Dose in Diagnostic Radiology With Two DosimetersHealth Physics, 1994
- Guidance on personal dosimetry for occupational exposure in interventional radiologyJournal of Radiological Protection, 1994
- Guidelines for personnel radiation monitoring in the cardiac catheterization laboratoryCatheterization and Cardiovascular Diagnosis, 1993
- Interventional radiologists: occupational radiation doses and risks.Radiology, 1993
- The Relationship of Effective Dose to Personnel and Monitor Reading for Simulated Fluoroscopic Irradiation ConditionsHealth Physics, 1993