Abstract
Surge is one of the main rotor dynamic instability limiting the operation of centrifugal compressors. This paper proposes an active surge control scheme for magnetically suspended centrifugal compressors (MSCCs) using a variable equilibrium point approach. Multiple uncertainties caused by magnetic air gap adjustment are considered for the active magnetic bearing (AMB) control systems. By using the combination of analytical model and finite element method, the perturbation of bearing force parameters, including force-current factor and force-displacement factor, are analyzed. The model uncertainties caused by the perturbation of the power amplifier parameters are identified through the on-line frequency sweep excitation. Based on the uncertainties analysis of AMB control system, a μ-synthesis-based controller is designed for the axial magnetic bearing system to suppress the vibration caused by surge. The experiments demonstrate that the proposed method can suppress surge and improve the reliability of the system by using automatic magnetic air gap adjustment of AMB-rotor system.
Funding Information
  • National Natural Science Foundation of China (61822302)
  • National Key Research and Development Program of China (2016YFB0500804)

This publication has 18 references indexed in Scilit: