Metal in Total Hip Arthroplasty: Wear Particles, Biology, and Diagnosis
Authors:
- Derek F. AmanatullahDADerek F. Amanatullah
- Mark G. SucherMSMark G. Sucher
- George F. BonadurerGBGeorge F. Bonadurer
- Gavin C. PereiraGPGavin C. Pereira
- Michael J. TauntonMTMichael J. Taunton
- 1 November 2016
- journal article
- review article
- Published by SLACK, Inc. in Orthopedics
- Vol. 39 (6) , 371-379
Abstract
Total hip arthroplasty (THA) has been performed for nearly 50 years. Between 2006 and 2012, more than 600,000 metal-on-metal THA procedures were performed in the United States. This article reviews the production of metal wear debris in a metal-on-metal articulation and the interaction of cobalt and chromium ions that ultimately led to a dramatic decline in the use of metal-on-metal THA articulations. Additionally, the article reviews mechanisms of metal wear, the biologic reaction to cobalt and chromium ions, the clinical presentation of failing metal-on-metal articulations, and current diagnostic strategies. Further, the article discusses the use of inflammatory markers, metal ion levels, radiographs, metal artifact reduction sequence magnetic resonance imaging, and ultrasound for failed metal-on-metal THA procedures. When adopting new technologies, orthopedic surgeons must weigh the potential increased benefits against the possibility of new mechanisms of failure. Metal-on-metal bearings are a prime example of the give and take between innovation and clinical results, especially in the setting of an already successful procedure such as THA. [Orthopedics.2016; 39(6):371–379.]Keywords
This publication has 92 references indexed in Scilit:
- Pseudotumour Formation Due to Tribocorrosion at the Taper Interface of Large Diameter Metal on Polymer Modular Total Hip ReplacementsThe Journal of Arthroplasty, 2013
- Blood metal ion testing is an effective screening tool to identify poorly performing metal-on-metal bearing surfacesBone & Joint Research, 2013
- Management of failed metal-on-metal total hip arthroplastyWorld Journal of Orthopedics, 2012
- Effects of cobalt and chromium ions at clinically equivalent concentrations after metal-on-metal hip replacement on human osteoblasts and osteoclasts: Implications for skeletal healthBone, 2011
- Femoral Head Size Does Not Affect Ion Values in Metal-on-Metal Total HipsClinical Orthopaedics and Related Research, 2011
- Silent soft tissue pathology is common with a modern metal-on-metal hip arthroplastyActa Orthopaedica, 2011
- Early failures cause concernBMJ, 2010
- Cancer risk is not increased after conventional hip arthroplastyActa Orthopaedica, 2010
- Projections of Primary and Revision Hip and Knee Arthroplasty in the United States from 2005 to 2030Journal of Bone and Joint Surgery, 2007
- TNF-α secretion and macrophage mortality induced by cobalt and chromium ions in vitro-Qualitative analysis of apoptosisBiomaterials, 2003