Pedicle screw anchorage of carbon fiber-reinforced PEEK screws under cyclic loading
Open Access
- 1 March 2018
- journal article
- research article
- Published by Springer Nature in European Spine Journal
- Vol. 27 (8) , 1775-1784
Abstract
Pedicle screw loosening is a common and significant complication after posterior spinal instrumentation, particularly in osteoporosis. Radiolucent carbon fiber-reinforced polyetheretherketone (CF/PEEK) pedicle screws have been developed recently to overcome drawbacks of conventional metallic screws, such as metal-induced imaging artifacts and interference with postoperative radiotherapy. Beyond radiolucency, CF/PEEK may also be advantageous over standard titanium in terms of pedicle screw loosening due to its unique material properties. However, screw anchorage and loosening of CF/PEEK pedicle screws have not been evaluated yet. The aim of this biomechanical study therefore was to evaluate whether the use of this alternative nonmetallic pedicle screw material affects screw loosening. The hypotheses tested were that (1) nonmetallic CF/PEEK pedicle screws resist an equal or higher number of load cycles until loosening than standard titanium screws and that (2) PMMA cement augmentation further increases the number of load cycles until loosening of CF/PEEK screws.Keywords
This publication has 40 references indexed in Scilit:
- Radiolucent Carbon Fiber–Reinforced Pedicle Screws for Treatment of Spinal Tumors: Advantages for Radiation Planning and Follow-Up ImagingWorld Neurosurgery, 2017
- Perturbation effects of the carbon fiber‐PEEK screws on radiotherapy dose distributionJournal of Applied Clinical Medical Physics, 2017
- Predictive validity of preoperative CT scans and the risk of pedicle screw loosening in spinal surgeryArchives of orthopaedic and trauma surgery, 2016
- Pedicle screw loosening: a clinically relevant complication?European Spine Journal, 2015
- Reduced loosening rate and loss of correction following posterior stabilization with or without PMMA augmentation of pedicle screws in vertebral fractures in the elderlyEuropean Journal of Trauma and Emergency Surgery, 2013
- Mid-range outcomes in 64 consecutive cases of multilevel fusion for degenerative diseases of the lumbar spineOrthopedic Reviews, 2010
- Metal-related artifacts in instrumented spine. Techniques for reducing artifacts in CT and MRI: state of the artEuropean Spine Journal, 2009
- PEEK biomaterials in trauma, orthopedic, and spinal implantsBiomaterials, 2007
- Metallic Artifacts in Magnetic Resonance Imaging of Patients With Spinal FusionSpine, 1998
- Pedicle screw fixation in spinal disorders: A European viewEuropean Spine Journal, 1997