(Nb, Ti)3Sn Superconducting Magnet Operated at 11 K in Vacuum Using High-Tc (Bi, Pb)2Sr2Ca2Cu3O10 Current Leads

Authors:
  • KWKazuo Watanabe
    Kazuo Watanabe
  • YYYutaka Yamada
    Yutaka Yamada
  • JSJunji Sakuraba
    Junji Sakuraba
  • FHFumiaki Hata
    Fumiaki Hata
  • CCChin Kung Chong
    Chin Kung Chong
  • THTsuginori Hasebe
    Tsuginori Hasebe
  • MIMamoru Ishihara
    Mamoru Ishihara

Abstract
A conduction-cooled superconducting magnet using high-T c oxide current leads was successfully demonstrated. We succeeded in constructing the (Nb, Ti)3Sn multifilamentary superconducting magnet system without liquid helium, which is operated at 11 K in vacuum using a cryocooler and generates a magnetic field of 4.6 T in a 50 mm bore (38 mm room temperature bore). Use of (Bi, Pb)2Sr2Ca2Cu3O10 current leads effectively contributed to realization of the compact cryostat with large current leads of 500 A.