Focused ion beam milling of vitreous water: prospects for an alternative to cryo‐ultramicrotomy of frozen‐hydrated biological samples
- 1 April 2006
- journal article
- Published by Wiley in Journal of Microscopy
- Vol. 222 (1) , 42-47
Abstract
Summary: The feasibility of using a focused ion beam (FIB) for the purpose of thinning vitreously frozen biological specimens for transmission electron microscopy (TEM) was explored. A concern was whether heat transfer beyond the direct ion interaction layer might devitrify the ice. To test this possibility, we milled vitreously frozen water on a standard TEM grid with a 30‐keV Ga+ beam, and cryo‐transferred the grid to a TEM for examination. Following FIB milling of the vitreous ice from a thickness of approximately 1200 nm to 200–150 nm, changes characteristic of heat‐induced devitrification were not observed by TEM, in either images or diffraction patterns. Although numerous technical challenges remain, it is anticipated that ‘cryo‐FIB thinning’ of bulk frozen‐hydratred material will be capable of producing specimens for TEM cryo‐tomography with much greater efficiency than cryo‐ultramicrotomy, and without the specimen distortions and handling difficulties of the latter.Keywords
This publication has 19 references indexed in Scilit:
- Towards high-resolution three-dimensional imaging of native mammalian tissue: Electron tomography of frozen-hydrated rat liver sectionsJournal of Structural Biology, 2006
- Cutting artefacts and cutting process in vitreous sections for cryo-electron microscopyJournal of Structural Biology, 2005
- New insights into the structural organization of eukaryotic and prokaryotic cytoskeletons using cryo-electron tomographyExperimental Cell Research, 2004
- Direct visualization of receptor arrays in frozen‐hydrated sections and plunge‐frozen specimens of E. coli engineered to overproduce the chemotaxis receptor TsrJournal of Microscopy, 2004
- Site-specific 3D Imaging of Cells and Tissues Using DualBeam TechnologyMicroscopy and Microanalysis, 2004
- An oscillating cryo‐knife reduces cutting‐induced deformation of vitreous ultrathin sectionsJournal of Microscopy, 2003
- The next ice age: cryo-electron tomography of intact cellsTrends in Cell Biology, 2003
- Cutting artefacts on ultrathin cryosections of biological bulk specimensMicron, 1994
- Cryosectioning of plant material frozen at high pressureJournal of Microscopy, 1991
- Cryo-electron microscopy of vitrified specimensQuarterly Reviews of Biophysics, 1988