Stability Analysis of the Grid-Tied VSC Considering the Influence of Short Circuit Ratio and X/R
- 27 April 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 69 (1) , 129-133
Abstract
The grid impedance ratio X/R (GIR) and the short circuit ratio (SCR) are the indexes that widely applied to the stability analysis of power systems integrated with voltage source converters (VSC). Based on the assumption that GIR is large enough, the impacts of grid resistances are neglected in most studies. In this brief, the impact mechanisms of grid impedance are analyzed by single-input and single-output (SISO) transfer functions under different GIR conditions. It is found that the decrease of GIR has both “enhancement effect” and “reduction effect” on SISO transfer function magnitudes, while the “reduction effect” is stronger than the “enhancement effect”. When $\mathrm {GIR} \in [f_{0}/f_{\mathrm{ pll}}, \infty$ ), the interaction behaves between the grid impedance and phase-locked loop (PLL), and it mainly has impacts on the magnitude-frequency curve. When $\mathrm {GIR} \in [0, f_{0}/f_{\mathrm{ pll}}$ ), the interaction behaves among the phase of grid impedance, PLL and current loop, and it mainly has impacts on the phase-frequency curve. Simulations are carried on MATLAB to verify the effectiveness of the proposed analysis.Keywords
Funding Information
- State Grid Corporation of China (XT71-19-020)
- Research on the Topology of the Voltage Source Converter for Stand-Alone Renewable Generation Integration System
This publication has 15 references indexed in Scilit:
- SISO Transfer Functions for Stability Analysis of Grid-Connected Voltage-Source ConvertersIEEE Transactions on Industry Applications, 2019
- Stability Analysis of Grid-Connected Voltage-Source Converters Using SISO ModelingIEEE Transactions on Power Electronics, 2018
- Analysis and design of vector control for VSC-HVDC connected to weak gridsCSEE Journal of Power and Energy Systems, 2017
- Small-Signal Stability Assessment of Power Electronics Based Power Systems: A Discussion of Impedance- and Eigenvalue-Based MethodsIEEE Transactions on Industry Applications, 2017
- Impact of Short-Circuit Ratio and Phase-Locked-Loop Parameters on the Small-Signal Behavior of a VSC-HVDC ConverterIEEE Transactions on Power Delivery, 2014
- Impedance Modeling and Analysis of Grid-Connected Voltage-Source ConvertersIEEE Transactions on Power Electronics, 2014
- Connecting wind power plant with weak grid - Challenges and solutions2013
- Impedance-Based Stability Criterion for Grid-Connected InvertersIEEE Transactions on Power Electronics, 2011
- Stability of a Variable-Speed Permanent Magnet Wind Generator With Weak AC GridsIEEE Transactions on Power Delivery, 2010
- Input-Admittance Calculation and Shaping for Controlled Voltage-Source ConvertersIEEE Transactions on Industrial Electronics, 2007