Parallel MRI reconstruction using variance partitioning regularization
Authors:
- Fa‐Hsuan LinFLFa‐Hsuan Lin
- Fu‐Nien WangFWFu‐Nien Wang
- Seppo P. AhlforsSASeppo P. Ahlfors
Open Access
- 26 September 2007
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 58 (4) , 735-744
Abstract
Multiple receivers can be utilized to enhance the spatiotemporal resolution of MRI by employing the parallel imaging technique. Previously, we have reported the L‐curve Tikhonov regularization technique to mitigate noise amplification resulting from the geometrical correlations between channels in a coil array. Nevertheless, one major disadvantage of regularized image reconstruction is lengthy computational time in regularization parameter estimation. At a fixed noise level, L‐curve regularization parameter estimation was also found not to be robust across repetitive measurements, particularly for low signal‐to‐noise ratio (SNR) acquisitions. Here we report a computationally efficient and robust method to estimate the regularization parameter by partitioning the variance of the noise‐whitened encoding matrix based on the estimated SNR of the aliased pixel set in parallel MRI data. The proposed Variance Partitioning Regularization (VPR) method can improve computational efficiency by 2–5‐fold, depending on image matrix sizes and acceleration rates. Our anatomical and functional MRI results show that the VPR method can be applied to both static and dynamic MRI experiments to suppress noise amplification in parallel MRI reconstructions for improved image quality. Magn Reson Med 58:735–744, 2007.Keywords
This publication has 22 references indexed in Scilit:
- Detecting and adjusting for artifacts in fMRI time series dataNeuroImage, 2005
- Bayesian analysis of the neuromagnetic inverse problem with ℓ-norm priorsNeuroImage, 2005
- Multilevel linear modelling for FMRI group analysis using Bayesian inferenceNeuroImage, 2004
- Parallel imaging reconstruction using automatic regularizationMagnetic Resonance in Medicine, 2004
- Reduction of Gradient Acoustic Noise in MRI Using SENSE-EPINeuroImage, 2002
- Design of a SENSE‐optimized high‐sensitivity MRI receive coil for brain imagingMagnetic Resonance in Medicine, 2002
- Tailored SMASH image reconstructions for robust in vivo parallel MR imagingMagnetic Resonance in Medicine, 2000
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Non-convergence of the L-curve regularization parameter selection methodInverse Problems, 1996
- Analysis of fMRI Time-Series RevisitedNeuroImage, 1995